sysmgr:SwitchOverAlert
To configure sysmgr switch over alert in embedded event manager.
Telemetry Sensor Path(s)
Configurable Properties
| PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES |
|---|---|---|---|
| adminSt | sysmgr:AdminState (scalar:Enum8) |
State to configure sysmgr switch over alert | SELECTION: 0 - enable 1 - disable DEFAULT: disable |
| applet | string:Basic |
Applet name used to override default policy of switch over alert. | A sequence of characters |
| count | scalar:Uint32 |
Expected Number of switch over to trigger event [1-65000] | RANGE: [1 , 65000] |
| time | scalar:Uint32 |
Expected Time interval to trigger event, in seconds [1-4294967295] | RANGE: [1 , 4294967295] |
Operational Properties
| PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
|---|---|---|---|
| operSt | sysmgr:OperState (scalar:Enum8) |
Operational status set by sysmgr | SELECTION: 0 - unknown 1 - enabled 2 - disabled DEFAULT: unknown |
Internal Properties
| PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
|---|---|---|---|
| modTs | mo:TStamp (scalar:Date) |
The time when this object was last modified. | SELECTION: 0 - never DEFAULT: never |
| status | mo:ModificationStatus (scalar:Bitmask32) |
Modification status | SELECTION: 2 - created 4 - modified 8 - deleted 16 - replaced |