dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX.
This MO is created implicitly to represent a circuit between two end-points |
|
├
|
fabric:Domain
Abstraction of fabric. Represents an
instance of generic fabric domain.
|
|
|
├
|
fabric:External
Abstraction of external fabric. Represents an
instance of generic external fabric domain.
|
|
|
|
├
|
fabric:EthMonLan A container for all Ethernet monitoring sessions on a specific Fabric Interconnect. |
|
|
|
├
|
fabric:ExternalEstc An abstract class for External Storage Target Connectivity (ESTC)
endpoints.
Abstraction of external External Storage Target Connectivity (ESTC) fabric.
Represents an instance of generic External ESTC fabric domain.
|
|
|
|
|
├
|
fabric:EthEstc Container for External Storage Target Connectivity (ESTC) Objects
that are specific to a Fabric Interconnect.
|
|
|
|
|
├
|
fabric:FcEstc A logical FC port channel on a Fabric Interconnect, for connectivity
to an external FC storage, using an FC port channel. |
|
|
|
├
|
fabric:FcMonSan A container for all Fibre Channel monitoring sessions on a specific Fabric Interconnect. |
|
|
|
├
|
fabric:FlowMon An abstract representation of the collection of monitors associated with an
interface in a given direction (tx/rx). It may include multiple monitors and
an interface. Currently only the virtual interfaces are supported. |
|
|
|
├
|
fabric:Lan
Abstraction of external LAN fabric. Represents an
instance of generic external LAN fabric domain.
|
|
|
|
|
├
|
fabric:EthLan Represents an Ethernet fabric, which contains the
user-configured VLANs, Ethernet interfaces and Ethernet
port channel interfaces.
In a UCS HA configuration, there are two Ethernet Fabrics,
A and B. Each fabric can contain a distinct set of configured
VLANs, Ethernet interfaces and port channel interfaces.
The VLAN may be configured per Ethernet fabric (i.e. fabric A
or fabric B) or per Lan Cloud, in which case the VLAN wi... |
|
|
|
├
|
fabric:Mon An abstract representation of a monitoring session (SPAN).
A monitoring session typically includes a destination port where monitored traffic will be sent,
and zero or more monitored source ports. |
|
|
|
|
├
|
fabric:EthMon An Ethernet monitoring session (SPAN), which includes one Ethernet destination port
where monitored traffic will be sent, and zero or more Ethernet source ports. |
|
|
|
|
├
|
fabric:FcMon A Fibre Channel monitoring session (SPAN), which includes one FC destination port
where monitored traffic will be sent, and zero or more FC source ports. |
|
|
|
├
|
fabric:San
Abstraction of external SAN fabric. Represents an
instance of generic external SAN fabric domain.
|
|
|
|
|
├
|
fabric:FcSan Represents a SAN fabric, which contains the
user-configured VSANs, Fibre Channel (FC) interfaces
and FC port channel interfaces.
In a UCS HA configuration, there are two SAN Fabrics,
A and B. Each fabric can contain a distinct set of configured
VSANs, FC interfaces and port channel interfaces.
The VSAN may be configured per SAN fabric (i.e. fabric A
or fabric B) or per San Cloud, in which case the VSAN will
be configure... |
|
|
├
|
fabric:Internal
Abstraction of internal fabric. Represents an
instance of generic internal fabric domain.
|
|
|
|
├
|
fabric:InternalDceSrv
Abstraction of internal server fabric. Represents an
instance of generic internal server fabric domain.
|
|
|
|
|
├
|
fabric:DceSrv
Internal DCE server domain.
This object is a container for server configuration objects.
|
|
├
|
fabric:SubGroup
A SubGroup contains ports which are made availabe by connecting a break-out cable to an
aggregated port. Example in UCS-Mini a 40GB Scalability
port is connected to a 4x10GB breakout cable to get 4 10GB ports.
|
|
├
|
fabric:SwSubGroup
A SwSubGroup contains ports which are made availabe by connecting a break-out cable to an
aggregated port. (For FcoeVsanPortEp and EthVlanPortEp) Example in UCS-Mini a 40GB Scalability
port is connected to a 4x10GB breakout cable to get 4 10GB ports.
|
|
|
|
├
|
network:CIoEp
Port Channel/Aggregation Interface End Point abstraction
|
|
|
|
|
├
|
adaptor:CIoEp
Represents UCD termination of
Port Channel Interface (Port Channel/Bundle/LAG etc)
|
|
|
|
|
|
├
|
adaptor:ExternalPc Abstract representation of network facing port channel interface
on a server adaptor. |
|
|
|
|
|
|
├
|
adaptor:ExtIfPc Abstract representation of network facing port channel interface
on a server adaptor. |
|
|
|
|
|
|
|
├
|
adaptor:ExtEthIfPc
Network facing Ethernet port channel interface on a server adaptor.
For example, on a network adaptor installed on a UCS blade, this MO represents
the Ethernet port channel interface connected to the IO Module on the UCS chassis.
In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
|
|
|
|
|
├
|
ether:CIoEp
Represents UCD termination of
Port Channel Interface (Port Channel/Bundle/LAG etc)
|
|
|
|
|
├
|
fabric:CIoEp
An abstract representation of a logical Port Channel Interface.
Concrete subclasses define specific port channel types, such as
Ethernet uplink Port Channel, FC uplink port channel, Ethernet storage port channel...
|
|
|
|
|
|
├
|
fabric:ExternalPc Abstraction of a logical, externally-connected port channel end-point
on a Fabric Interconnect.
Concrete sub-classes define specific endpoint types, such as Ethernet port channels,
or FC port channels.
|
|
|
|
|
|
|
├
|
fabric:EstcPc An abstract class for External Storage Target Connectivity (ESTC)
port channel endpoints.
|
|
|
|
|
|
|
|
├
|
fabric:EthEstcPc A logical Ethernet Port Channel on a Fabric Interconnect, for connectivity
to an external NAS storage.
This object is created explicitly by the user. Creation of this object
indicates that the terminated port will be a port channel connected to NAS storage.
|
|
|
|
|
|
|
|
├
|
fabric:EthVlanPc Represents an association between a VLAN and an Ethernet port channel.
This MO is added as a child of fabric:Vlan and indicates the specified Ethernet port channel
should carry the VLAN ID of the parent fabric:Vlan. |
|
|
|
|
|
|
├
|
fabric:LanPc An abstract representation of an Ethernet Port Channel Interface. |
|
|
|
|
|
|
|
├
|
fabric:EthLanPc An Ethernet Port Channel Interface, which aggregate multiple
Ethernet ports to increase the link throughput and increase redundancy
for higher availability.
This is configured by the API user.
|
|
|
|
|
|
|
├
|
fabric:SanPc An abstract representation of a Fibre Channel Port Channel Interface. |
|
|
|
|
|
|
|
├
|
fabric:FcSanPc A Fibre Channel (FB) Port Channel Interface, which aggregate multiple
FB ports to increase the link throughput and increase redundancy
for higher availability.
This is configured by the API user.
|
|
|
|
|
|
|
|
├
|
fabric:FcVsanPc Port-channel that attaches to the VSAN. This is configured by the admin. |
|
|
|
|
|
|
|
├
|
fabric:FcoeSanPc A FCoE Port Channel Interface, which aggregate multiple
FCoE uplink ports to increase the link throughput and increase redundancy
for higher availability.
This is configured by the API user.
|
|
|
|
|
|
|
|
├
|
fabric:FcoeVsanPc FCoE uplink Port-channel that attaches to the VSAN. This is configured by the admin. |
|
|
|
|
|
├
|
fabric:InternalPc Abstraction of a logical, internally-connected port channel end-point
on a Fabric Interconnect.
Concrete sub-classes define specific endpoint types, such as Ethernet port channels
to servers.
|
|
|
|
|
|
|
├
|
fabric:SwSrvPc Abstraction of a logical server-facing Ethernet port channel on a Fabric Interconnect.
|
|
|
|
|
|
|
|
├
|
fabric:DceSwSrvPc Represents a logical server-facing Ethernet port channel on a Fabric Interconnect.
A port channel object is created automatically by the system when the Link Grouping Preference
is set to "Port Channel" and the IO Module on the chassis supports port channeling.
|
|
|
|
|
├
|
sw:CIoEp
Representation of switching domain
(port-)channel connectivity end-point. Typically
specifies a port-channel configuration.
|
|
|
|
|
|
├
|
sw:BorderPc
Representation of switching border domain
(port-)channel connectivity end-point.
Specifies a port-channel configuration.
|
|
|
|
|
|
|
├
|
sw:LanPc
Represents a LAN Border Port Channel.
|
|
|
|
|
|
|
|
├
|
sw:EthLanPc
Represents a Ethernet LAN Border Port Channel.
|
|
|
|
|
|
|
├
|
sw:SanPc
Represents a SAN Border Port Channel.
|
|
|
|
|
|
|
|
├
|
sw:FcSanPc
Represents a FC SAN Border Port Channel.
|
|
|
|
|
├
|
adaptor:HostIf
Abstract Representation of a host-facing interface on a server adaptor.
Sub-classes represent specific types of interfaces such as Ethernet or Fibre Channel.
|
|
|
|
|
|
├
|
adaptor:HostEthIf
Representation of a host-facing Ethernet interface on a server adaptor.
A server adaptor has network facing interfaces (NIF), which provide network
connectivity to the network (through the IO Module for UCS blades)
and server facing interfaces (SIF), which are visible by the Operating System.
|
|
|
|
|
|
├
|
adaptor:HostFcIf
Representation of host-facing fibre channel interface on a server adaptor.
A server adaptor has network facing interfaces (NIF), which provide network
connectivity to the SAN fabric (through the IO Module for UCS blades)
and server facing interfaces (SIF), which are visible by the Operating System.
|
|
|
|
|
|
├
|
adaptor:HostServiceEthIf
This MO represents the Host facing interface on a server adaptor , that
is specifically used for netflow service vnics.
|
|
|
|
|
|
├
|
adaptor:ExtIf
Abstract representation of network facing adaptor interface on a server adaptor.
|
|
|
|
|
|
|
├
|
adaptor:ExtEthIf
Network facing Ethernet interface on a server adaptor.
For example, on a network adaptor installed on a UCS blade, this MO represents
the Ethernet interface connected to the IO Module on the UCS chassis.
In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
|
|
|
|
|
|
├
|
adaptor:PIoEp
Represents UCD termination of
IO Interface (Port)
|
|
|
|
|
|
├
|
ether:PIoEp Model for Port-Channel EPs
Represents UCD termination of
IO Interface (Port)
|
|
|
|
|
|
├
|
fabric:PIoEp
An abstract representation of a Universal Connectivity Domain (UCD) termination of
IO Interface (Port).
|
|
|
|
|
|
|
├
|
fabric:ExternalEp Abstraction of a logical, externally-connected IO end-point
on a Fabric Interconnect.
Concrete sub-classes define specific endpoint types, such as Ethernet uplinks,
FC uplinks, or SPAN destination ports.
|
|
|
|
|
|
|
|
|
├
|
fabric:AEthEstcEp Abstraction of a logical Ethernet port connected to external NAS storage.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:EthEstcEp A logical Ethernet port on a Fabric Interconnect for connectivity to an external NAS storage.
This object is created explicitly by the user. Creation of this object
indicates that the terminated port will be a single physical port connected to NAS storage.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:EthEstcPcEp A member of a logical Ethernet Port Channel
for External Storage Target Connectivity (ESTC).
This object is created explicitly by the user. Creation of this object
indicates that the terminated port will be a member of a port channel connected to NAS storage.
|
|
|
|
|
|
|
|
|
├
|
fabric:AFcEstcEp Abstraction of a logical FC port channel on a Fabric Interconnect, for connectivity
to an external FC storage, using an FC port channel. |
|
|
|
|
|
|
|
|
|
├
|
fabric:FcEstcEp A logical FC port channel member on a Fabric Interconnect, for connectivity
to an external FC storage, using an FC port channel. |
|
|
|
|
|
|
|
|
├
|
fabric:AFcoeEstcEp Abstraction of a logical FCoE port on a Fabric Interconnect, for connectivity
to an external FCoE storage port.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:FcoeEstcEp A logical FCoE port on a Fabric Interconnect for connectivity to an external FCoE storage port.
This object is created explicitly by the user. Creation of this object
indicates that the terminated port will be a single physical port connected to FCoE storage. |
|
|
|
|
|
|
|
├
|
fabric:LanEp Abstraction of a logical, externally-connected Ethernet interface.
Concrete sub-classes define specific endpoint types, such as Ethernet uplink ports,
or Ethernet Port Channel member ports.
|
|
|
|
|
|
|
|
|
├
|
fabric:AEthLanEp An abstract representation of an Uplink Ethernet Interface
on a Fabric Interconnect.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:EthLanEp An Uplink Ethernet Interface on the Fabric Interconnect,
representing the desired configuration of a single physical Ethernet port
connected to an upstream Layer 2 switch.
This is configured by the API user.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:EthLanPcEp A member of an Ethernet Port Channel interface,
representing a single Ethernet port member of a port channel.
This is configured by the API user.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:EthVlanPortEp Represents an association between a VLAN and an Ethernet port.
This MO is added as a child of fabric:Vlan and indicates the specified
Ethernet port should carry the VLAN ID of the parent fabric:Vlan. |
|
|
|
|
|
|
|
|
├
|
fabric:EthMonDestEp An Ethernet Destination Monitoring port.
This object is created by the API user and specifies a destination port
for network monitoring. Ethernet traffic specified in a monitoring session such as SPAN
will be sent to an Ethernet destination port.
|
|
|
|
|
|
|
|
|
├
|
fabric:FcMonDestEp A Fibre Channel Destination Monitoring port.
This object is created by the API user and specifies a destination port
for network monitoring. Fibre Channel traffic specified in a monitoring session such as SPAN
will be sent to a FC destination port.
|
|
|
|
|
|
|
|
├
|
fabric:SanEp Abstraction of a logical, externally-connected FC interface.
Concrete sub-classes define specific endpoint types, such as FC uplink ports,
or FC Port Channel member ports.
|
|
|
|
|
|
|
|
|
├
|
fabric:AFcSanEp An abstract representation of an Uplink Fibre Channel Interface
on a Fabric Interconnect.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:FcSanEp An Uplink Fibre Channel (FB) Interface on the Fabric Interconnect,
supporting a single physical FB port connected to an
upstream SAN switch.
This is configured by the API user.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:FcSanPcEp A member of a Fibre Channel Port Channel Interface,
representing a single Fibre Channel port member of a port channel.
This is configured by the API user.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:FcVsanPortEp FC Port that attaches to the parent VSAN.
Indicates the parent VSAN will be configured on the specified FC port (FC storage port or FC uplink port).
This is configured explicitly by the user. |
|
|
|
|
|
|
|
|
|
├
|
fabric:FcoeVsanPortEp FCoE Port that attaches to the parent VSAN.
Indicates the parent VSAN will be configured on the specified FCoE port.
This is configured explicitly by the user. |
|
|
|
|
|
|
|
|
├
|
fabric:AFcoeSanEp An abstract representation of an Uplink Fcoe interface
on a Fabric Interconnect.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:FcoeSanEp An Uplink FCoE uplink Interface on the Fabric Interconnect,
This is configured by the API user.
|
|
|
|
|
|
|
|
|
|
├
|
fabric:FcoeSanPcEp A member of a FCoE Port Channel Interface,
representing a single FCoE port member of a FCoE port channel.
This is configured by the API user.
|
|
|
|
|
|
|
├
|
fabric:InternalEp Abstraction of logical Configuration Objects for server-related objects.
Concrete subclasses are defined to model server-related configuration objects, such as
logical server-facing ports on the Fabric Interconnect and logical chassis.
|
|
|
|
|
|
|
|
├
|
fabric:ComputeEp
Abstraction for blade end-point.
identifies compute resource presence.
|
|
|
|
|
|
|
|
|
├
|
fabric:CartridgePhEp
Represents compute resource fru presence in
the system. This object also remembers logical
resource binding to corresponding compute unit.
|
|
|
|
|
|
|
|
|
├
|
fabric:ComputePhEp
Represents compute resource fru presence in
the system. This object also remembers logical
resource binding to corresponding compute unit.
|
|
|
|
|
|
|
|
├
|
fabric:EquipmentEp
Abstraction for equipment end-point.
identifies generic compute resource presence.
|
|
|
|
|
|
|
|
|
├
|
fabric:SwChPhEp A logical representation of a FEX or UCS chassis.
This object contains the FRU information about a FEX or chassis, and
is used to handle decommissionning and recommissionning of a FEX or UCS chassis. |
|
|
|
|
|
|
|
├
|
fabric:SwSrvEp Abstraction of a logical server-facing Ethernet port on a Fabric Interconnect.
|
|
|
|
|
|
|
|
|
├
|
fabric:ADceSwSrvEp Abstraction of a logical server-facing Ethernet port on a Fabric Interconnect.
A server-facing port is a switch port connected to servers (on a UCS chassis or FEX).
|
|
|
|
|
|
|
|
|
|
├
|
fabric:DceSwSrvEp End Point of a logical server-facing Ethernet port on a Fabric Interconnect.
This object is created explicitly by the user. Creation of this object
indicates that the physical port referred by this logical port will be
configured as a server-facing port on the Fabric Interconnect.
The physical port will be configured as a single Ethernet port (i.e. no port channel).
|
|
|
|
|
|
|
|
|
|
├
|
fabric:DceSwSrvPcEp Represents a logical server-facing Ethernet port channel member on a Fabric Interconnect.
This object is not supported.
|
|
|
|
|
|
├
|
mgmt:If Encapsulates the configuration of a CIMC management interface. |
|
|
|
|
|
|
├
|
port:IntFIo Abstraction of a physical port on an IO Card.
|
|
|
|
|
|
|
|
├
|
port:SwitchIntFIo Abstraction of a physical port on an IO Card.
IO Modules on a UCS chassis and IO modules on a FEX have ports
that are connected to a Fabric Interconnect and ports that
are connected to the servers.
Concrete subclasses are defined to model server-facing and switch-facing
ports.
|
|
|
|
|
|
|
|
|
├
|
ether:ServerIntFIo Represents a server-facing physical Ethernet port on an IO Card.
IO Modules on a UCS chassis and IO modules on a FEX have Ethernet ports
that are connected to a Fabric Interconnect and Ethernet ports that
are connected to the servers.
This object represents the Ethernet ports on the IO Card that are
connected to the servers.
|
|
|
|
|
|
|
|
|
├
|
ether:SwitchIntFIo Represents a switch-facing physical Ethernet port on an IO Card.
IO Modules on a UCS chassis and IO modules on a FEX have Ethernet ports
that are connected to a Fabric Interconnect and Ethernet ports that
are connected to the servers.
This object represents the Ethernet ports on the IO Card that are
connected to the Fabric Interconnect.
|
|
|
|
|
|
|
├
|
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
|
|
|
|
|
|
|
|
├
|
ether:PIo An inventoried Physical Ethernet Port on a physical device,
such as a L2 switch, FEX, or IOM module on a Chassis.
The "ifRole" property specifies if this is a server-facing port or
uplink Ethernet port.
|
|
|
|
|
|
|
|
├
|
fc:PIo An inventoried Physical Fibre Channel port on a physical device,
such as a Fabric Interconnect or FEX. |
|
|
|
|
|
├
|
sw:PIoEp
Representation of switching domain
physical connectivity end-point. Typically
specifies a physical port or connection.
|
|
|
|
|
|
|
├
|
sw:BorderEp
Representation of switching border domain
physical connectivity end-point. Specifies
a physical port or connection terminating on
external fabric.
|
|
|
|
|
|
|
|
├
|
sw:LanEp
Represents a LAN Border Physical Port.
|
|
|
|
|
|
|
|
|
├
|
sw:EthLanEp
Represents a Ethernet LAN Border Physical Port.
|
|
|
|
|
|
|
|
├
|
sw:SanEp
Represents a SAN Border Physical Port.
|
|
|
|
|
|
|
|
|
├
|
sw:FcSanEp
Represents a FC SAN Border Physical Port.
|
|
|
|
|
|
|
|
├
|
sw:EthMonDestEp switch:EthMonDestEp is the MO that is used to send the configuration of an ethernet SPAN destination port to portAG |
|
|
|
|
|
|
|
├
|
sw:FcMonDestEp switch:FcMonDestEp is the MO that is used to send the configuration of an FC SPAN destination port to portAG |
|
|
|
|
|
|
├
|
sw:PhysEtherEp Represents the desired configuration state of an Ethernet port
on a Fabric Interconnect. |
|
|
|
|
|
|
├
|
sw:PhysFcEp Represents the desired configuration state of a FC port
on a Fabric Interconnect. |
|
|
|
├
|
network:VnetEp
Port Channel/Aggregation Interface End Point abstraction
|
|
|
|
|
|
├
|
fabric:AVlan An abstract representation of a named Layer 2 network. |
|
|
|
|
|
|
├
|
fabric:BHVlan Black Hole vlan - used as native vlan for all fcoe storage ports |
|
|
|
|
|
|
├
|
fabric:Vlan A user-created object representing a named Layer 2 bridge
in an Ethernet Fabric or LAN Cloud.
Create an instance of this MO to configure a VLAN on the
UCS Fabric Interconnect (A or B).
To create a VLAN on both UCS Fabric Interconnects, create this MO as a child
of fabricLanCloud.
|
|
|
|
|
|
|
├
|
fabric:VlanEp
Represents a VLAN on a border port or appliance port.
This MO is created implicitly. |
|
|
|
|
|
|
├
|
fabric:Vsan A VSAN provides the ability to create completely isolated fabric topologies, with its own set of fabric services,
on top of a scalable common physical infrastructure. As each VSAN possesses its own zoning service, zoning is then
configured within each VSAN independently and has no affect on any other VSAN and zoning service |
|
|
|
|
|
|
├
|
fabric:VsanEp VSAN Ep attaches to the fabricSanEp MO (FC Port)
This is an artifact of creating FcVsanPortEp under a VSAN
|
|
├
|
port:Group A collection of physical ports on a device.
A port group is created implicitly during device discovery of IO devices
such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis.
All the ports in a portGroup have the same type (i.e. FC, Ethernet).
|
|
├
|
port:SubGroup
A SubGroup contains ports which are made availabe by connecting a break-out cable to an
aggregated port. Example in UCS-Mini a 40GB Scalability
port is connected to a 4x10GB breakout cable to get 4 10GB ports.
|
|
├
|
sw:Domain
Representation of switch domain.
Switch domain is a collection of
connectivity end-points of containing
network element terminating on a common
fabric.
|
|
|
├
|
sw:BorderDomain
Representation of switch border domain.
Switch border domain is a collection of
connectivity end-points of containing
network element terminating on a common
external fabric.
|
|
|
|
├
|
sw:LanBorder
LAN BORDER
Represents Switch LAN Border Domain
which is a collection of LAN physical
ports and port channels and their
configurations. This is an abstract class.
|
|
|
|
|
├
|
sw:EthLanBorder
Represents Switch Ethernet LAN Border Domain
which is a collection of Ethernet physical
ports and port channels and their configurations.
|
|
|
|
├
|
sw:SanBorder
Represents Switch SAN Border Domain
which is a collection of SAN physical
ports their configurations.
This is an abstract class.
|
|
|
|
|
├
|
sw:FcSanBorder
Represents Switch FC LAN Border Domain
which is a collection of FC physical
ports and their configurations.
|
|
├
|
sw:SubGroup
A SubGroup contains ports which are made availabe by connecting a break-out cable to an
aggregated port. Example in UCS-Mini a 40GB Scalability