FSM sam:dme:SwEthLanBorderDeploy

Rule ID:251

This FSM is used to configure VLANs, VLAN compression groups and physical Ethernet ports on the Fabric Interconnects.
Applies to MO: sw:EthLanBorder

Name: Deploy
Stage: post-explicit
Message: Uplink eth port configuration on switchId(FSM:sam:dme:SwEthLanBorderDeploy)

Begin State: UpdateVlanGroups


States
 UpdateVlanGroups
Configures the VLAN compression groups.

  On Success: UpdateConnectivity
  On Fail:
  Restart: INIT_RESET
  Retry: RETRY_FOREVER
  Retry Exhaust: RETRY_EXHAUST_RESET_FSM
  Retry Interval: 60000
  Retry Count: 20
  Unavailable: UNAVAIL_RETRY
  Message: VLAN group configuration on switchId(FSM-STAGE:sam:dme:SwEthLanBorderDeploy:UpdateVlanGroups)

  Notify:
   Target: sam:portAG
   Instance: active
   Purpose: mod
   Custom: true
   Data: sw:EthLanBorder
   Method: FsmSwEthLanBorderDeployUpdateVlanGroups

 UpdateConnectivity
Configures the following elements:
  • VLANs
  • Ethernet uplink ports and port channels
  • Ethernet appliance ports and port channels

  On Success:
  On Fail:
  Restart: INIT_RESET
  Retry: RETRY_FINITE
  Retry Exhaust: RETRY_EXHAUST_RESET_FSM
  Retry Interval: 60000
  Retry Count: 20
  Unavailable: UNAVAIL_RETRY
  Message: Uplink eth port configuration on switchId(FSM-STAGE:sam:dme:SwEthLanBorderDeploy:UpdateConnectivity)

  Notify:
   Target: sam:portAG
   Instance: active
   Purpose: mod
   Custom: true
   Data: sw:EthLanBorder
   Method: FsmSwEthLanBorderDeployUpdateConnectivity