FSM sam:dme:ComputePhysicalTurnup

Rule ID:595

NO COMMENTS
Applies to MO: compute:Physical

Name: Turnup
Stage: post-explicit
Message: Power-on server dn(FSM:sam:dme:ComputePhysicalTurnup)

Begin State: CheckPowerAvailability


States
 CheckPowerAvailability
NO COMMENTS

  On Success: PowerDeployWait
  On Fail:
  Restart: INIT_RESET
  Retry: RETRY_FINITE
  Retry Exhaust: RETRY_EXHAUST_RESET_FSM
  Retry Interval: 60000
  Retry Count: 20
  Unavailable: UNAVAIL_RETRY
  Message: Check if power can be allocated to server serverId(FSM-STAGE:sam:dme:ComputePhysicalTurnup:CheckPowerAvailability)

  Notify:
   Target:
   Instance: active
   Purpose: mod
   Custom: true
   Data:

 PowerDeployWait
NO COMMENTS

  On Success: Execute
  On Fail:
  Restart: INIT_RESET
  Retry: RETRY_FINITE
  Retry Exhaust: RETRY_EXHAUST_RESET_FSM
  Retry Interval: 5000
  Retry Count: 20
  Unavailable: UNAVAIL_RETRY
  Message: Waiting for power allocation to server serverId(FSM-STAGE:sam:dme:ComputePhysicalTurnup:PowerDeployWait)

  Notify:
   Target:
   Instance: active
   Purpose: mod
   Custom: true
   Data:

 Execute
NO COMMENTS

  On Success:
  On Fail:
  Restart: INIT_RESET
  Retry: RETRY_FINITE
  Retry Exhaust: RETRY_EXHAUST_RESET_FSM
  Retry Interval: 40000
  Retry Count: 20
  Unavailable: UNAVAIL_RETRY
  Message: Power-on server dn(FSM-STAGE:sam:dme:ComputePhysicalTurnup:Execute)

  Notify:
   Target: sam:bladeAG
   Instance: active
   Purpose: mod
   Custom: false
   Data:
   Method: FsmComputePhysicalTurnupExecute