FSM sam:dme:SysdebugLogExportPolicyConfigure

Rule ID:1371

NO COMMENTS
Applies to MO: sysdebug:LogExportPolicy

Name: Configure
Stage: post-explicit
Message: configure log file export service(FSM:sam:dme:SysdebugLogExportPolicyConfigure)

Begin State: Local


States
 Local
@stageFaultExplanation
Cisco UCS Manager could not set the configurations in the primary Fabric Interconnect for log file transfer to remote server.
@stageFaultRecommendedAction
If you see this fault, take the following actions:


  1. Execute the show tech-support command and contact Cisco Technical Support.

@stageRemoteFaultExplanation
Cisco UCS Manager could not set the configurations in the primary Fabric Interconnect for log file transfer to remote server.
@stageRemoteFaultRecommendedAction
If you see this fault, take the following actions:


  1. Execute the show tech-support command and contact Cisco Technical Support.

  On Success: Peer
  On Fail:
  Restart: INIT_RESET
  Retry: RETRY_FINITE
  Retry Exhaust: RETRY_EXHAUST_RESET_FSM
  Retry Interval: 60000
  Retry Count: 20
  Unavailable: UNAVAIL_RETRY
  Message: configuring log file export service on local(FSM-STAGE:sam:dme:SysdebugLogExportPolicyConfigure:Local)

  Notify:
   Target: sam:dcosAG
   Instance: self
   Purpose: mod
   Custom: false
   Data:
   Method: FsmSysdebugLogExportPolicyConfigureLocal

 Peer
@stageFaultExplanation
Cisco UCS Manager could not set the configurations in the subordinate Fabric Interconnect (FI) for log file transfer to remote server. This fault typically appears for one of the following reasons:
  • The subordinate FI is not reachable.
  • The subordinate FI is experiencing an internal system error on applying the configuration.
@stageFaultRecommendedAction
If you see this fault, take the following actions:


  1. Check the FI cluster state to ensure that the subordinate FI is reachable and functioning correctly. If the subordinate FI is down, take appropriate corrective actions so that the UCS cluster goes into HA ready state.
  2. If the HA state of the primary and subordinate FIs are good, execute the show tech-support command and contact Cisco Technical Support.

@stageRemoteFaultExplanation
Cisco UCS Manager could not set the configurations in the subordinate Fabric Interconnect (FI) for log file transfer to remote server. This fault typically appears for one of the following reasons:
  • The subordinate FI is not reachable.
  • The subordinate FI is experiencing an internal system error on applying the configuration.
@stageRemoteFaultRecommendedAction
If you see this fault, take the following actions:


  1. Check the FI cluster state to ensure that the subordinate FI is reachable and functioning correctly. If the subordinate FI is down, take appropriate corrective actions so that the UCS cluster goes into HA ready state.
  2. If the HA state of the primary and subordinate FIs are good, execute the show tech-support command and contact Cisco Technical Support.

  On Success:
  On Fail:
  Restart: INIT_RESET
  Retry: RETRY_FINITE
  Retry Exhaust: RETRY_EXHAUST_RESET_FSM
  Retry Interval: 60000
  Retry Count: 20
  Unavailable: UNAVAIL_RETRY
  Message: configuring log file export service on peer(FSM-STAGE:sam:dme:SysdebugLogExportPolicyConfigure:Peer)

  Notify:
   Target: sam:dcosAG
   Instance: peer
   Purpose: mod
   Custom: false
   Data:
   Method: FsmSysdebugLogExportPolicyConfigurePeer