Fault fltEthpmIfPortDownInfraEpg
                

Rule ID:532


Explanation:
This fault occurs when a port is down and is in use for epg

Recommended Action:
If you see this fault, take the following actions


  1. Check the port connectivity
  2. Remove the configuration or administratively shut the port if the port is not in use
  3. For mcp-loop-err-disable, this could be due to a loop in the network. Check the config to resolve any loops
  4. For lacp suspended ports, this could be because the remote device is not transmitting LACP PDUs. Please check remote device LACP configuration
  5. If the above action did not resolve the issue, create a tech-support file and contact Cisco TAC.

Raised on MO: ethpm:If

Fault Name: fltEthpmIfPortDownInfraEpg

Unqualified API Name: portDownInfraEpg
Code: F0532
Applied Mo DN Format:

Type: communications
Cause: interface-physical-down
Severity: critical
Weight: 100
Tags:
Message: Port is down, reason:operStQual(operErrDisQual), used by:usage

Help:

Triggered By:
          operSt equals down
         and
         not
           usage contains blacklist
         and
          usage equals epg
         and
          operStQual not equals mac-pinning
        or
         not
           usage contains blacklist
         and
          usage contains epg
         and
          operStQual not equals mac-pinning
         and
          lastLinkStChg not equals 0ull
         and
          operSt equals down