Fault fltTopSystemOobMgmtIPInUse
                

Rule ID:2573


Explanation:
This fault occurs when the controller out-of-band management IP address cannot be assigned as it is in use (local or remote).

Recommended Action:
If you see this fault, take the following actions:


  1. Identify the interface that is using this IP.
    For example:
    You can use linux utility 'arping' to locate the MAC address of interface using the IP address.
    arping -I oobmgmt -c 1
  2. If above action did not resolve the issue, create a tech-support file and contact Cisco TAC.


Raised on MO: top:System

Fault Name: fltTopSystemOobMgmtIPInUse

Unqualified API Name: oobMgmtIPInUse
Code: F2573
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys
     sys

Type: config
Cause: oobmgmt-ip-in-use
Severity: major
Weight: 100
Tags:
Message: On apic name of fabric fabricDomain with a hostname name, oobMgmtAddr of name is already in use.

Help:

Triggered By:
        configIssues contains oobmgmt-ip-in-use