Fault fltFhsRaGuardOperStDown
Explanation:
This fault occurs when the
operational state of the RA Guard fhs feature is changed
to due to cfg-err or bd-vlan-down reasons on the leaf
Recommended Action:
To recover from this fault,
try the following actions
Fault Name: fltFhsRaGuardOperStDown
Unqualified API Name: operStDown
Code: F2677
Applied Mo DN Format:
topology/pod-[id]/node-[id]/sys/fhs/inst/dom-[encap]/bd-[encap]/raguard
sys/fhs/inst/dom-[encap]/bd-[encap]/raguard
Type: operational
Cause: fhs-oper-state-failed
Severity: major
Weight: 100
Tags:
Message:
Operational State of FHS RA Guard sub feature configuration is operationally down on node with id id with name name from pod podId of fabric fabricDomain, reason:operStQual
Help:
Triggered By:
operStQual equals cfg-error
or
operStQual equals cfg-not-supported
or
operStQual equals bd-vlan-down