Fault fltCoppFilterPrefilterHardwareError
                

Rule ID:2924


Explanation:
This fault occurs when CoPP prefilter ACL entry installation failed due to hardware programming error.

Recommended Action:
To recover from this fault, try the following actions


  1. Look at any configuration issues.
  2. Verify the configuration is correct/complete.
  3. Delete the CoPP prefilter ACL entry and add it back.
  4. If the above actions did not resolve the issue, try rebooting the switch using CLI or GUI.

Raised on MO: copp:Filter

Fault Name: fltCoppFilterPrefilterHardwareError

Unqualified API Name: prefilterHardwareError
Code: F2924
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/copp/rulep-[name]-[type]/filter-[action]-prio-[prio]-proto-[ipProto]-src-[srcAddr]-dst-[dstAddr]-srcFromP-[srcPortFrom]-srcToP-[srcPortTo]-dstFromP-[dstPortFrom]-dstToP-[dstPortTo]
     sys/copp/rulep-[name]-[type]/filter-[action]-prio-[prio]-proto-[ipProto]-src-[srcAddr]-dst-[dstAddr]-srcFromP-[srcPortFrom]-srcToP-[srcPortTo]-dstFromP-[dstPortFrom]-dstToP-[dstPortTo]

Type: operational
Cause: copp-prefilter-acl-entry-installation-failed-due-to-hardware-error
Severity: major
Weight: 100
Tags:
Message: CoPP prefilter ACL entry installation failure on node id of fabric hostname name reason:operStQual

Help:

Triggered By:
        operStQual equals hardware-err