Fault fltUnifiedportsIfInvalidPortType
                

Rule ID:3041


Explanation:
This fault occurs when unified port type configuration is invalid.

Recommended Action:
To recover from this fault, try the following actions


  1. Check if the FC Ports are configured in groups of 4. If not Correct it.
  2. Check if the Ports are configured in Mixed Mode (Ex : 1-4 Ethernet 5-8 FC 9-12 Ethernet). If yes Consolidate them in Two Groups.

Raised on MO: unifiedports:If

Fault Name: fltUnifiedportsIfInvalidPortType

Unqualified API Name: invalidPortType
Code: F3041
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/unifiedports/if-[id]
     sys/unifiedports/if-[id]

Type: config
Cause: invalid-port-type
Severity: critical
Weight: 100
Tags:
Message: Unified Port type configuration is invalid, reason: operStReason (operStQual) on node id of fabric fabricDomain with a hostname name

Help:

Triggered By:
        operSt equals invalid