Fault fltL2RsPathDomAttDot1qTunnelNotSupported
                

Rule ID:2713


Explanation:
This fault occurs when a QinQ tunnel is deployed on an unsupported platform ToR

Recommended Action:
To recover from this fault, try the following actions


  1. Delete dot1q tunnel deployment from node
  2. If the above actions did not resolve the issue, generate the show tech-support file and contact Cisco TAC.

Raised on MO: l2:RsPathDomAtt

Fault Name: fltL2RsPathDomAttDot1qTunnelNotSupported

Unqualified API Name: dot1qTunnelNotSupported
Code: F2713
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/ctxsubstitute-[encap]/bd-[fabEncap]/qinq-[encap]/rspathDomAtt-[tDn]
     sys/ctxsubstitute-[encap]/bd-[fabEncap]/qinq-[encap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/inst-[name]/bd-[fabEncap]/qinq-[encap]/rspathDomAtt-[tDn]
     sys/inst-[name]/bd-[fabEncap]/qinq-[encap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/ctx-[encap]/bd-[fabEncap]/qinq-[encap]/rspathDomAtt-[tDn]
     sys/ctx-[encap]/bd-[fabEncap]/qinq-[encap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/ctxsubstitute-[encap]/bd-[fabEncap]/vxlan-[encap]/rspathDomAtt-[tDn]
     sys/ctxsubstitute-[encap]/bd-[fabEncap]/vxlan-[encap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/inst-[name]/bd-[fabEncap]/vxlan-[encap]/rspathDomAtt-[tDn]
     sys/inst-[name]/bd-[fabEncap]/vxlan-[encap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/ctx-[encap]/bd-[fabEncap]/vxlan-[encap]/rspathDomAtt-[tDn]
     sys/ctx-[encap]/bd-[fabEncap]/vxlan-[encap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/ctxsubstitute-[encap]/bd-[fabEncap]/vlan-[encap]/rspathDomAtt-[tDn]
     sys/ctxsubstitute-[encap]/bd-[fabEncap]/vlan-[encap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/inst-[name]/bd-[fabEncap]/vlan-[encap]/rspathDomAtt-[tDn]
     sys/inst-[name]/bd-[fabEncap]/vlan-[encap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/ctx-[encap]/bd-[fabEncap]/vlan-[encap]/rspathDomAtt-[tDn]
     sys/ctx-[encap]/bd-[fabEncap]/vlan-[encap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/ctxsubstitute-[encap]/bd-[fabEncap]/rspathDomAtt-[tDn]
     sys/ctxsubstitute-[encap]/bd-[fabEncap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/inst-[name]/bd-[fabEncap]/rspathDomAtt-[tDn]
     sys/inst-[name]/bd-[fabEncap]/rspathDomAtt-[tDn]
     topology/pod-[id]/node-[id]/sys/ctx-[encap]/bd-[fabEncap]/rspathDomAtt-[tDn]
     sys/ctx-[encap]/bd-[fabEncap]/rspathDomAtt-[tDn]

Type: operational
Cause: bd-provisioning-failed
Severity: warning
Weight: 100
Tags:
Message: Dot1q Tunnel is not supported on Node id name because platform ports are qinqCapable

Help:

Triggered By:
        qinqCapable not equals capable