Fault fltL2BDL3outCustomFault
Explanation:
This fault occurs when a L3 external
virtual IF/floating L3out is deployed on an
unsupported platform TOR
Recommended Action:
To recover from this fault, take the
following actions
Fault Name: fltL2BDL3outCustomFault
Unqualified API Name: l3outCustomFault
Code: F3685
Applied Mo DN Format:
topology/pod-[id]/node-[id]/sys/ctxsubstitute-[encap]/bd-[fabEncap]
sys/ctxsubstitute-[encap]/bd-[fabEncap]
topology/pod-[id]/node-[id]/sys/inst-[name]/bd-[fabEncap]
sys/inst-[name]/bd-[fabEncap]
topology/pod-[id]/node-[id]/sys/ctx-[encap]/bd-[fabEncap]
sys/ctx-[encap]/bd-[fabEncap]
Type: config
Cause: l3vif-platform-unsupported
Severity: warning
Weight: 100
Tags:
Message:
Virtual logical interface profile deployed on Node id name is not supported on this ToR
Help:
Triggered By:
vlanmgrCustFaultBmp contains l3vif-platform-unsupported