Class equipment:Chassis (CONCRETE)

Class ID:703
Encrypted: false - Exportable: false - Persistent: true
Privileges: [admin, pn-equipment, pn-maintenance, pn-policy]
SNMP OID: .1.3.6.1.4.1.9.9.719.1.38.24

A physical unit that can accomodate multiple blade servers. For example, the Cisco UCS 5108 Blade Server Chassis is six rack units (6RU) high, can mount in an industry-standard 19-inch rack and uses front-to-back cooling.


Naming Rules
RN FORMAT: chassis-[id]

    [1] PREFIX=chassis- PROPERTY = id




DN FORMAT: 

[0] sys/chassis-[id]

                



Containers Hierarchies
top:Root This class represents the root element in the object hierarchy. All managed objects in the system are descendants of the Root element.
 ├
top:System Provides general information about this system, such as the name, IP address and current time.
 
 ├
equipment:Chassis


Contained Hierarchy
equipment:Chassis
 ├
compute:Blade A physical compute blade. Physical compute item in blade form factor.

Skipping contained mo's. Too many contained mo's: 57
 ├
compute:BoardController Managed object representing a blade PLD such as CPLD, EPLD, and FPGAs for sanfrancisco blade.
 
 ├
mgmt:Controller Controller
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 ├
event:Inst
 
 
 ├
fabric:Locale
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:Path
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 ├
mgmt:Connection
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ControllerFsm
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 ├
mgmt:ControllerFsmTask
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 ├
dhcp:Acquired
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 ├
mgmt:IfFsmTask
 
 
 ├
mgmt:Interface
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:KvmCertificate
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 ├
compute:Cartridge A physical compute cartridge.
 
 ├
compute:ServerUnit A server instance on a cartridge.

Skipping contained mo's. Too many contained mo's: 53
 ├
compute:PsuControl
 ├
equipment:ChassisFsm
 
 ├
equipment:ChassisFsmStage
 ├
equipment:ChassisFsmTask
 ├
equipment:ChassisStats
 
 ├
equipment:ChassisStatsHist
 ├
equipment:ComputeConn
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
equipment:FanModule Represents an inventoried Fan module. This object is created implicitly when a Fan module is detected during equipment discovery.
 
 ├
equipment:Fan Represents a fan in a Fan module.
 
 
 ├
equipment:FanStats
 
 
 
 ├
equipment:FanStatsHist
 
 
 ├
equipment:NetworkElementFanStats
 
 
 
 ├
equipment:NetworkElementFanStatsHist
 
 
 ├
equipment:RackUnitFanStats
 
 
 
 ├
equipment:RackUnitFanStatsHist
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
equipment:FanModuleStats
 
 
 ├
equipment:FanModuleStatsHist
 
 ├
equipment:Led
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
equipment:IOCard Represents an inventoried IO Card on a device, such as an IO module on a UCS chassis or FEX. This object is created implicitly when an IO Card is detected during hardware discovery.
 
 ├
equipment:IOCardBaseFsm
 
 
 ├
equipment:IOCardBaseFsmStage
 
 ├
equipment:IOCardBaseFsmTask
 
 ├
equipment:IOCardFsm
 
 
 ├
equipment:IOCardFsmStage
 
 ├
equipment:IOCardFsmTask
 
 ├
equipment:IOCardStats
 
 
 ├
equipment:IOCardStatsHist
 
 ├
equipment:Led
 
 ├
equipment:POST
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
fault:SuppressTask
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
trig:LocalSched A locally defined user-defined schedule. The schedule is contained locally by the Managed Object that needs the schedule, as opposed to being referred by name.
 
 
 
 ├
trig:SchedWindow Scheduled Window.
 
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:Controller Controller
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 ├
event:Inst
 
 
 ├
fabric:Locale
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:Path
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 ├
mgmt:Connection
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ControllerFsm
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 ├
mgmt:ControllerFsmTask
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 ├
dhcp:Acquired
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 ├
mgmt:IfFsmTask
 
 
 ├
mgmt:Interface
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:KvmCertificate
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
port:Group A collection of physical ports on a device. A port group is created implicitly during device discovery of IO devices such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis. All the ports in a portGroup have the same type (i.e. FC, Ethernet).
 
 
 ├
ether:ServerIntFIoPc
 
 
 
 ├
ether:ServerIntFIoPcEp
 
 
 ├
ether:SwitchIntFIoPc
 
 
 
 ├
ether:NiErrStats
 
 
 
 
 ├
ether:NiErrStatsHist
 
 
 
 ├
ether:SwitchIntFIoPcEp
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
port:IntFIo Abstraction of a physical port on an IO Card.
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 ├
equipment:Xcvr
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
lldp:Acquired
 
 
 
 ├
network:IfStats
 
 
 
 ├
port:DomainEp
 
 
 
 ├
port:PIoFsm
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 ├
port:PIoFsmTask
 
 
 ├
port:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 ├
network:IfStats
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 ├
port:PIoFsmTask
 ├
equipment:Led
 ├
equipment:Poolable
 
 ├
equipment:PoolPolicyRef Reference to pooling policy that caused the equipment to be added to pool.
 ├
equipment:Psu Represents an inventoried Power Supply Unit. This object is created implicitly when a Power Supply Unit is detected during equipment discovery.
 
 ├
equipment:FexPsuInputStats
 
 
 ├
equipment:FexPsuInputStatsHist
 
 ├
equipment:Led
 
 ├
equipment:PsuFsm
 
 
 ├
equipment:PsuFsmStage
 
 ├
equipment:PsuFsmTask
 
 ├
equipment:PsuInputStats Mike asked me to create a new object for the PSU input stats.
 
 
 ├
equipment:PsuInputStatsHist
 
 ├
equipment:PsuOutputStats
 
 
 ├
equipment:PsuOutputStatsHist
 
 ├
equipment:PsuStats
 
 
 ├
equipment:PsuStatsHist
 
 ├
equipment:RackUnitPsuStats
 
 
 ├
equipment:RackUnitPsuStatsHist
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 ├
firmware:BootUnit
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:UcscInfo
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 ├
firmware:UcscInfo
 ├
equipment:SharedIOModule Represents an inventoried Shared IO Module on a device
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:Controller Controller
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 ├
event:Inst
 
 
 ├
fabric:Locale
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:Path
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 ├
mgmt:Connection
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ControllerFsm
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 ├
mgmt:ControllerFsmTask
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 ├
dhcp:Acquired
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 ├
mgmt:IfFsmTask
 
 
 ├
mgmt:Interface
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:KvmCertificate
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
port:Group A collection of physical ports on a device. A port group is created implicitly during device discovery of IO devices such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis. All the ports in a portGroup have the same type (i.e. FC, Ethernet).
 
 
 ├
ether:ServerIntFIoPc
 
 
 
 ├
ether:ServerIntFIoPcEp
 
 
 ├
ether:SwitchIntFIoPc
 
 
 
 ├
ether:NiErrStats
 
 
 
 
 ├
ether:NiErrStatsHist
 
 
 
 ├
ether:SwitchIntFIoPcEp
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
port:IntFIo Abstraction of a physical port on an IO Card.
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 ├
equipment:Xcvr
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
lldp:Acquired
 
 
 
 ├
network:IfStats
 
 
 
 ├
port:DomainEp
 
 
 
 ├
port:PIoFsm
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 ├
port:PIoFsmTask
 
 
 ├
port:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 ├
network:IfStats
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 ├
port:PIoFsmTask
 ├
equipment:SwitchIOCard Represents an inventoried FI-IOM Card on a UCS-Mini Chassis This object is created implicitly when an FI-IOM Card is detected during hardware discovery. TODO: This is model similar to IOCard currently however this does not behave like a IOCard (IOM) and some of the properties will be removed if not needed.
 
 ├
equipment:IOCardBaseFsm
 
 
 ├
equipment:IOCardBaseFsmStage
 
 ├
equipment:IOCardBaseFsmTask
 
 ├
equipment:IOCardStats
 
 
 ├
equipment:IOCardStatsHist
 
 ├
equipment:SwitchIOCardFsm
 
 
 ├
equipment:SwitchIOCardFsmStage
 
 ├
equipment:SwitchIOCardFsmTask
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:Controller Controller
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 ├
event:Inst
 
 
 ├
fabric:Locale
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:Path
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 ├
mgmt:Connection
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ControllerFsm
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 ├
mgmt:ControllerFsmTask
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 ├
dhcp:Acquired
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 ├
mgmt:IfFsmTask
 
 
 ├
mgmt:Interface
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:KvmCertificate
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
port:Group A collection of physical ports on a device. A port group is created implicitly during device discovery of IO devices such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis. All the ports in a portGroup have the same type (i.e. FC, Ethernet).
 
 
 ├
ether:ServerIntFIoPc
 
 
 
 ├
ether:ServerIntFIoPcEp
 
 
 ├
ether:SwitchIntFIoPc
 
 
 
 ├
ether:NiErrStats
 
 
 
 
 ├
ether:NiErrStatsHist
 
 
 
 ├
ether:SwitchIntFIoPcEp
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
port:IntFIo Abstraction of a physical port on an IO Card.
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 ├
equipment:Xcvr
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
lldp:Acquired
 
 
 
 ├
network:IfStats
 
 
 
 ├
port:DomainEp
 
 
 
 ├
port:PIoFsm
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 ├
port:PIoFsmTask
 
 
 ├
port:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 ├
network:IfStats
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 ├
port:PIoFsmTask
 ├
equipment:SystemIOController Represents a SIOC on a Colusa 2 chassis
 
 ├
compute:BoardController Managed object representing a blade PLD such as CPLD, EPLD, and FPGAs for sanfrancisco blade.
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
equipment:SharedIOModule Represents an inventoried Shared IO Module on a device
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 ├
port:Group A collection of physical ports on a device. A port group is created implicitly during device discovery of IO devices such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis. All the ports in a portGroup have the same type (i.e. FC, Ethernet).
 
 
 
 ├
ether:ServerIntFIoPc
 
 
 
 
 ├
ether:ServerIntFIoPcEp
 
 
 
 ├
ether:SwitchIntFIoPc
 
 
 
 
 ├
ether:NiErrStats
 
 
 
 
 
 ├
ether:NiErrStatsHist
 
 
 
 
 ├
ether:SwitchIntFIoPcEp
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
port:IntFIo Abstraction of a physical port on an IO Card.
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 ├
network:IfStats
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 ├
port:PIoFsmTask
 
 
 
 ├
port:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 
 ├
network:IfStats
 
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 
 ├
port:PIoFsmTask
 
 ├
equipment:SiocTempStats
 
 
 ├
equipment:SiocTempStatsHist
 
 ├
equipment:SystemIOControllerFsm
 
 
 ├
equipment:SystemIOControllerFsmStage
 
 ├
equipment:SystemIOControllerFsmTask
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:Controller Controller
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 ├
event:Inst
 
 
 ├
fabric:Locale
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:Path
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 ├
mgmt:Connection
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ControllerFsm
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 ├
mgmt:ControllerFsmTask
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 ├
dhcp:Acquired
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 ├
mgmt:IfFsmTask
 
 
 ├
mgmt:Interface
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:KvmCertificate
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 ├
event:Inst
 ├
fabric:Locale
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 ├
fabric:ANetGroupRef
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:Cmclan
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:NetflowMonitorRef
 
 
 ├
sw:Ulan
 
 
 ├
sw:Vlan
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:Vsan A Vsan
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 ├
fabric:Path
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Cmclan
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 ├
sw:Ulan
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 ├
fabric:PathConn
 
 
 
 ├
fabric:PathEp
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fabric:PathEp
 
 
 
 ├
port:TrustMode
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
fault:SuppressTask
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
trig:LocalSched A locally defined user-defined schedule. The schedule is contained locally by the Managed Object that needs the schedule, as opposed to being referred by name.
 
 
 ├
trig:SchedWindow Scheduled Window.
 ├
firmware:Activity
 ├
firmware:ActivityTrigger
 ├
firmware:ImageLock
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
mgmt:Controller Controller
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 ├
event:Inst
 
 ├
fabric:Locale
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Cmclan
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 ├
sw:Ulan
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 ├
fabric:Path
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:PathConn
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fabric:PathEp
 
 
 
 
 ├
port:TrustMode
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 ├
firmware:BootUnit
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:UcscInfo
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 ├
firmware:UcscInfo
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 ├
mgmt:Connection
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:ControllerFsm
 
 
 ├
mgmt:ControllerFsmStage
 
 ├
mgmt:ControllerFsmTask
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 ├
dhcp:Acquired
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 ├
mgmt:IfFsm
 
 
 
 ├
mgmt:IfFsmStage
 
 
 ├
mgmt:IfFsmTask
 
 ├
mgmt:Interface
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:Vnet
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 ├
mgmt:KvmCertificate
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 ├
mgmt:Vnet
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 ├
mgmt:UsbNicMgmtIf
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 ├
vnic:IpV4ProfDerivedAddr
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 ├
power:Budget Define chassis budget, extend it to include minimum consumption level The FSM properties to deploy chassis budget will also be contained here
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
power:ProfiledPower Power consumption limit of servers from profiling or catalog
 ├
ses:Enclosure
 
 ├
ses:DiskSlotEp
 ├
storage:Controller
 
 ├
equipment:InventoryStatus Hardware component inventory status.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 ├
firmware:BootUnit
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:UcscInfo
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 ├
lstorage:ControllerDef
 
 
 ├
lstorage:ControllerModeConfig
 
 
 ├
lstorage:ControllerQualifier
 
 ├
mgmt:Controller Controller
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 ├
event:Inst
 
 
 ├
fabric:Locale
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:Path
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 ├
mgmt:Connection
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ControllerFsm
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 ├
mgmt:ControllerFsmTask
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 ├
dhcp:Acquired
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 ├
mgmt:IfFsmTask
 
 
 ├
mgmt:Interface
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:KvmCertificate
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
storage:Drive
 
 ├
storage:EmbeddedStorage Class for embedded storage of NVMe HHHL form factor
 
 ├
storage:Enclosure
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
storage:EnclosureDiskSlotEp Indicates the disk slot in an enclosure. When the slot is populated, peerDn references the disk present. This is the same as the LocalDiskSlotEp mo. This mo was created because of a conflict between LocalDiskSlotEp and LocalDisk. Both have the same rn and therefore cannot be contained under the same container.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
storage:ControllerRef Represents ownership for server,controller combination
 
 
 ├
storage:EnclosureFsm
 
 
 
 ├
storage:EnclosureFsmStage
 
 
 ├
storage:EnclosureFsmTask
 
 
 ├
storage:HddMotherBoardTempStats
 
 
 
 ├
storage:HddMotherBoardTempStatsHist
 
 
 ├
storage:LocalDiskLocalDisk identifies the physical storage device, a group of LocalDisks can be partitioned into VirtualDrive (or LunDisk in the old code). All of them are child MOs under Storage::Controller.
 
 
 
 ├
equipment:LocatorLed
 
 
 
 
 ├
equipment:LocatorLedFsm
 
 
 
 
 
 ├
equipment:LocatorLedFsmStage
 
 
 
 
 ├
equipment:LocatorLedFsmTask
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
mgmt:Controller Controller
 
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fabric:Locale
 
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 
 ├
mgmt:Connection
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 
 ├
mgmt:Interface
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 
 ├
storage:ControllerEp
 
 
 
 ├
storage:DiskEnvStats
 
 
 
 
 ├
storage:DiskEnvStatsHist
 
 
 
 ├
storage:LocalDiskFsm
 
 
 
 
 ├
storage:LocalDiskFsmStage
 
 
 
 ├
storage:LocalDiskFsmTask
 
 
 
 ├
storage:LocalDiskPartition identifies a partition as identified by fdisk
 
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 
 ├
storage:SasPort Represents SAS port on disk
 
 
 
 ├
storage:SsdHealthStats
 
 
 
 
 ├
storage:SsdHealthStatsHist
 
 ├
storage:LocalDiskLocalDisk identifies the physical storage device, a group of LocalDisks can be partitioned into VirtualDrive (or LunDisk in the old code). All of them are child MOs under Storage::Controller.
 
 
 ├
equipment:LocatorLed
 
 
 
 ├
equipment:LocatorLedFsm
 
 
 
 
 ├
equipment:LocatorLedFsmStage
 
 
 
 ├
equipment:LocatorLedFsmTask
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 ├
storage:ControllerEp
 
 
 ├
storage:DiskEnvStats
 
 
 
 ├
storage:DiskEnvStatsHist
 
 
 ├
storage:LocalDiskFsm
 
 
 
 ├
storage:LocalDiskFsmStage
 
 
 ├
storage:LocalDiskFsmTask
 
 
 ├
storage:LocalDiskPartition identifies a partition as identified by fdisk
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 ├
storage:SasPort Represents SAS port on disk
 
 
 ├
storage:SsdHealthStats
 
 
 
 ├
storage:SsdHealthStatsHist
 
 ├
storage:LocalDiskConfigDef LocalDiskConfig
 
 
 ├
lstorage:Security
 
 
 
 ├
lstorage:DriveSecurity
 
 
 
 
 ├
lstorage:Local
 
 
 
 
 ├
lstorage:Remote
 
 
 
 
 
 ├
lstorage:Login This is used to store the login information for KMIP server
 
 
 ├
storage:LocalDiskPartition identifies a partition as identified by fdisk
 
 ├
storage:LocalDiskEp Represents SAS/SATA connectivity to a physical disk. This object is created to indicate a SCSI controller has physical connectivity to \ the specified {@link storage:LocalDisk}. In addition, when the disk is accessed \ through a SAS link, the SAS expander must be configured to expose the physical disk to the SCSI controller.
 
 ├
storage:LocalLun
 
 ├
storage:MezzFlashLife SAS Expander MO :end % Flash Life
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
storage:NvmeStats
 
 
 ├
storage:NvmeStatsHist
 
 ├
storage:NvmeStorageAdding a new MO for all NVMe related properties. Right now it has only one field but this will increase going forward. Idea is to segregate NVMe specific properties from generic storage controller MO
 
 ├
storage:OnboardDevice OnBoard Device This MO can represent any component that is part of a storage controller etc
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 ├
storage:RaidBattery RAID battery to capture battery faults
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 ├
storage:TransportableFlashModule TFM to capture flash module powered by supercap which is a type of RaidBattery
 
 ├
storage:VirtualDrive Storage physical drives are grouped as Drive Group, a drive group then can be partitioned into virtual drives. Each virtual drive appears as a physical device to the O/S.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
storage:ControllerEp
 
 
 ├
storage:LunDisk A logical unit number, or LUN, is a number used to identify a logical storage unit. A LUN may be used with any device which supports read/write operations, but is most often used to refer to a logical disk as created on a SAN. LunDisk refers to the logical disk, it's deprecated and replaced with VirtualDrive
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 ├
storage:ScsiLunRef ScsiLunRef is to keep track of the location of LUN item defined storage profile (or profile def). This meta-data is guaranteed to be persisted in the storage target.
 
 
 ├
storage:VDMemberEp Reference to LocalDisk to build up a VirtualDrive
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
storage:VirtualDriveEp
 ├
storage:Enclosure
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
storage:EnclosureDiskSlotEp Indicates the disk slot in an enclosure. When the slot is populated, peerDn references the disk present. This is the same as the LocalDiskSlotEp mo. This mo was created because of a conflict between LocalDiskSlotEp and LocalDisk. Both have the same rn and therefore cannot be contained under the same container.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
storage:ControllerRef Represents ownership for server,controller combination
 
 ├
storage:EnclosureFsm
 
 
 ├
storage:EnclosureFsmStage
 
 ├
storage:EnclosureFsmTask
 
 ├
storage:HddMotherBoardTempStats
 
 
 ├
storage:HddMotherBoardTempStatsHist
 
 ├
storage:LocalDiskLocalDisk identifies the physical storage device, a group of LocalDisks can be partitioned into VirtualDrive (or LunDisk in the old code). All of them are child MOs under Storage::Controller.
 
 
 ├
equipment:LocatorLed
 
 
 
 ├
equipment:LocatorLedFsm
 
 
 
 
 ├
equipment:LocatorLedFsmStage
 
 
 
 ├
equipment:LocatorLedFsmTask
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 ├
storage:ControllerEp
 
 
 ├
storage:DiskEnvStats
 
 
 
 ├
storage:DiskEnvStatsHist
 
 
 ├
storage:LocalDiskFsm
 
 
 
 ├
storage:LocalDiskFsmStage
 
 
 ├
storage:LocalDiskFsmTask
 
 
 ├
storage:LocalDiskPartition identifies a partition as identified by fdisk
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 ├
storage:SasPort Represents SAS port on disk
 
 
 ├
storage:SsdHealthStats
 
 
 
 ├
storage:SsdHealthStatsHist
 ├
storage:SasExpander Represents a SAS Expander that exposes the physical disks to the SCSI controller
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 ├
firmware:BootUnit
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:UcscInfo
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 ├
mgmt:Controller Controller
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 ├
event:Inst
 
 
 ├
fabric:Locale
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:Path
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 ├
mgmt:Connection
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ControllerFsm
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 ├
mgmt:ControllerFsmTask
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 ├
dhcp:Acquired
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 ├
mgmt:IfFsmTask
 
 
 ├
mgmt:Interface
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:KvmCertificate
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
storage:OnboardDevice OnBoard Device This MO can represent any component that is part of a storage controller etc
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 ├
storage:SasUpLink Represents SAS uplink connected to SAS Expander
 ├
storage:VirtualDriveContainer
 
 ├
storage:VirtualDrive Storage physical drives are grouped as Drive Group, a drive group then can be partitioned into virtual drives. Each virtual drive appears as a physical device to the O/S.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
storage:ControllerEp
 
 
 ├
storage:LunDisk A logical unit number, or LUN, is a number used to identify a logical storage unit. A LUN may be used with any device which supports read/write operations, but is most often used to refer to a logical disk as created on a SAN. LunDisk refers to the logical disk, it's deprecated and replaced with VirtualDrive
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 ├
storage:ScsiLunRef ScsiLunRef is to keep track of the location of LUN item defined storage profile (or profile def). This meta-data is guaranteed to be persisted in the storage target.
 
 
 ├
storage:VDMemberEp Reference to LocalDisk to build up a VirtualDrive
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
vnic:RackServerDiscoveryProfile RackServerDiscoveryProfile is used for profiles, user can not mutate these
 
 ├
sw:Vlan
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.


Inheritance
equipment:Item
 ├
equipment:Stateful
 
 ├
equipment:Holder
 
 
 ├
equipment:Chassis

Events
                



Faults
                equipment:Chassis:chassislimit-exceeded
equipment:Chassis:identity
equipment:Chassis:identity-unestablishable
equipment:Chassis:inaccessible-a
equipment:Chassis:inaccessible-b
equipment:Chassis:inoperable
equipment:Chassis:invalid-fru
equipment:Chassis:physical-security
equipment:Chassis:powerProblem
equipment:Chassis:seeprom-inoperable
equipment:Chassis:thermalThresholdCritical
equipment:Chassis:thermalThresholdNonCritical
equipment:Chassis:thermalThresholdNonRecoverable
equipment:Chassis:unacknowledged
equipment:Chassis:unsupportedConnectivity



Fsms
                equipment:Chassis:Associate
equipment:Chassis:ChassisUpgrade
equipment:Chassis:Disassociate
equipment:Chassis:DynamicReallocation
equipment:Chassis:FwUpgrade
equipment:Chassis:OobStorageAdminCfg
equipment:Chassis:PowerCap
equipment:Chassis:PsuPolicyConfig
equipment:Chassis:RemoveChassis



Properties Summary
Defined in: equipment:Chassis
equipment:ChassisConfigProgressIndicator
          scalar:Enum8
ackProgressIndicator  (equipment:Chassis:ackProgressIndicator)
           NO COMMENTS
equipment:ChassisAdminState
          scalar:Enum8
adminState  (equipment:Chassis:adminState)
           NO COMMENTS
naming:UserLabel
          string:Basic
assetTag  (equipment:Chassis:assetTag)
           NO COMMENTS
reference:Object assignedToDn  (equipment:Chassis:assignedToDn)
           NO COMMENTS
equipment:Association
          scalar:Enum8
association  (equipment:Chassis:association)
           NO COMMENTS
equipment:Availability
          scalar:Enum8
availability  (equipment:Chassis:availability)
           NO COMMENTS
equipment:ChassisConfigState
          scalar:Enum8
configState  (equipment:Chassis:configState)
           NO COMMENTS
equipment:ConnectionStatus
          scalar:Bitmask8
connPath  (equipment:Chassis:connPath)
           NO COMMENTS
equipment:ConnectionStatus
          scalar:Bitmask8
connStatus  (equipment:Chassis:connStatus)
           NO COMMENTS
equipment:Discovery
          scalar:Enum8
discovery  (equipment:Chassis:discovery)
           NO COMMENTS
equipment:ConnectionStatus
          scalar:Bitmask8
discoveryStatus  (equipment:Chassis:discoveryStatus)
           NO COMMENTS
reference:Object fabricEpDn  (equipment:Chassis:fabricEpDn)
           NO COMMENTS
scalar:Uint64 fltAggr  (equipment:Chassis:fltAggr)
           NO COMMENTS
fsm:Descr
          string:Basic
fsmDescr  (equipment:Chassis:fsmDescr)
           NO COMMENTS
equipment:ChassisFsmFlags
          scalar:Bitmask64
fsmFlags  (equipment:Chassis:fsmFlags)
           NO COMMENTS
equipment:ChassisFsmStatus
          scalar:Enum32
fsmPrev  (equipment:Chassis:fsmPrev)
           NO COMMENTS
fsm:Progress
          scalar:UByte
fsmProgr  (equipment:Chassis:fsmProgr)
           NO COMMENTS
condition:ErrCode
          scalar:Uint32
fsmRmtInvErrCode  (equipment:Chassis:fsmRmtInvErrCode)
           NO COMMENTS
string:Basic fsmRmtInvErrDescr  (equipment:Chassis:fsmRmtInvErrDescr)
           NO COMMENTS
condition:RemoteInvRslt
          scalar:Bitmask32
fsmRmtInvRslt  (equipment:Chassis:fsmRmtInvRslt)
           NO COMMENTS
fsm:Descr
          string:Basic
fsmStageDescr  (equipment:Chassis:fsmStageDescr)
           NO COMMENTS
scalar:Date fsmStamp  (equipment:Chassis:fsmStamp)
           NO COMMENTS
equipment:ChassisFsmStatus
          scalar:Enum32
fsmStatus  (equipment:Chassis:fsmStatus)
           NO COMMENTS
scalar:UByte fsmTry  (equipment:Chassis:fsmTry)
           NO COMMENTS
equipment:Id
          scalar:Uint32
id  (equipment:Chassis:id)
           Overrides:equipment:Item:id
           NO COMMENTS
scalar:Date lcTs  (equipment:Chassis:lcTs)
           life cycle timestamp used for internal purposes
license:GracePeriod
          scalar:Uint64
licGP  (equipment:Chassis:licGP)
           NO COMMENTS
license:State
          scalar:Enum8
licState  (equipment:Chassis:licState)
           NO COMMENTS
network:SwitchId
          scalar:Enum8
managingInst  (equipment:Chassis:managingInst)
           NO COMMENTS
scalar:Date mfgTime  (equipment:Chassis:mfgTime)
           NO COMMENTS
equipment:ChassisIssues
          scalar:Bitmask64
operQualifier  (equipment:Chassis:operQualifier)
           NO COMMENTS
equipment:Operability
          scalar:Enum8
operState  (equipment:Chassis:operState)
           NO COMMENTS
equipment:PartNumber
          string:Basic
partNumber  (equipment:Chassis:partNumber)
           NO COMMENTS
equipment:ChassisPowerOperState
          scalar:Enum8
power  (equipment:Chassis:power)
           NO COMMENTS
equipment:Operability
          scalar:Enum8
seepromOperState  (equipment:Chassis:seepromOperState)
           NO COMMENTS
equipment:ServiceState
          scalar:Enum8
serviceState  (equipment:Chassis:serviceState)
           NO COMMENTS
equipment:SensorThresholdStatus
          scalar:Enum8
thermal  (equipment:Chassis:thermal)
           NO COMMENTS
string:Basic thermalStateQualifier  (equipment:Chassis:thermalStateQualifier)
           NO COMMENTS
naming:UserLabel
          string:Basic
usrLbl  (equipment:Chassis:usrLbl)
           Field to hold user label CSCta06454, CSCsx53838
scalar:Bool versionHolder  (equipment:Chassis:versionHolder)
           NO COMMENTS
string:Basic vid  (equipment:Chassis:vid)
           NO COMMENTS
Defined in: equipment:Stateful
equipment:OperQualifierReason
          string:Basic
operQualifierReason  (equipment:Stateful:operQualifierReason)
           NO COMMENTS
equipment:Operability
          scalar:Enum8
operability  (equipment:Stateful:operability)
           NO COMMENTS
equipment:Presence
          scalar:Enum8
presence  (equipment:Stateful:presence)
           NO COMMENTS
Defined in: equipment:Item
equipment:Model
          string:Basic
model  (equipment:Item:model)
           NO COMMENTS
equipment:Revision
          string:Basic
revision  (equipment:Item:revision)
           NO COMMENTS
equipment:Serial
          string:Basic
serial  (equipment:Item:serial)
           NO COMMENTS
equipment:Vendor
          string:Basic
vendor  (equipment:Item:vendor)
           NO COMMENTS
Defined in: mo:TopProps
mo:ModificationChildAction
          scalar:Bitmask32
childAction  (mo:TopProps:childAction)
          
reference:Object dn  (mo:TopProps:dn)
           The Distinguished Name (dn) unambiguously identifies an object in the system.
The dn provides a fully qualified path from the top of the object tree, all the way to the object. It is built as a sequence of relative names separated by the "/" character.
For example:
< ... dn = "sys/chassis-5/blade-2/adaptor-1" />
reference:RN rn  (mo:TopProps:rn)
           The Relative Name (rn) uniquely identifies an object within a given context.
Note that a dn is comprised of a sequence of relative names. For example, the context "sys/chassis-1/blade-1/adaptor-1/host-eth-2" can be thought of as the following expression:
dn = <root object>/{rn}/{rn}/{rn}/{rn}/{rn}.
The rn can then be used to identify the object (for instance, "adaptor-1") within the context:
<... rn ="../" />
mo:InstSaclType
          scalar:Bitmask8
sacl  (mo:TopProps:sacl)
           The system acl property for each Managed Object. br/> This property is a 8 bit mask and supports the following values :-
a: del
b: mod
c: addchild
d: cascade

By default all Managed Objects have the following permissions
a: del
b: mod
c: addchild
This property is persisted in the db. If this property has a value none
it means, the user has read only permissions on this object.
mo:ModificationStatus
          scalar:Bitmask32
status  (mo:TopProps:status)
           This property controls the life cycle of a managed object

Properties Detail

ackProgressIndicator

Type: equipment:ChassisConfigProgressIndicator
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
ack-not-in-progress 0 DISRUPTIVE!
ack-in-progress 1 NO COMMENTS
DEFAULT ack-not-in-progress(0) DISRUPTIVE!

adminState

Type: equipment:ChassisAdminState
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: admin
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
acknowledged 1 DISRUPTIVE!
re-acknowledge 2 - transient state; DISRUPTIVE! recommission chassis
decommission 3 Decommission chassis
remove 4 Remove chassis from inventory. Chassis must be physically removed
enable-port-channel 5 NO COMMENTS
disable-port-channel 6 NO COMMENTS
auto-acknowledge 7 auto-ack set on policy change
DEFAULT acknowledged(1) DISRUPTIVE!

assetTag

Type: naming:UserLabel
Primitive Type: string:Basic
Like: equipment:FruidInfo:assetTag
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "32"
        Allowed Chars:
            Regex: [a-zA-Z0-9\[\]!#$%()*+,-./:;@ _{|}˜?&]+
Comments:
NO COMMENTS

assignedToDn

Type: reference:Object
Refers: equipment:ChassisProfile
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS

association

Type: equipment:Association
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
none 0 NO COMMENTS
establishing 1 NO COMMENTS
associated 2 NO COMMENTS
removing 3 NO COMMENTS
failed 4 NO COMMENTS
throttled 5 NO COMMENTS
DEFAULT none(0) NO COMMENTS

availability

Type: equipment:Availability
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unavailable 0 NO COMMENTS
available 1 NO COMMENTS
DEFAULT unavailable(0) NO COMMENTS

childAction

Type: mo:ModificationChildAction
Primitive Type: scalar:Bitmask32
Units: null
Encrypted: false
Access: implicit
Category: TopLevelChildAction
Property Validators:
Comments:
Constants
deleteAll 16384u NO COMMENTS
ignore 4096u NO COMMENTS
deleteNonPresent 8192u NO COMMENTS
DEFAULT 0 This type is used to

configState

Type: equipment:ChassisConfigState
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
un-initialized 0 DISRUPTIVE!
un-acknowledged 1 NO COMMENTS
unsupported-connectivity 2 NO COMMENTS
ok 3 NO COMMENTS
removing 4 NO COMMENTS
ack-in-progress 6
evaluation 7 Used only for analyzing VIF NS change impact
acknowledged 8 NO COMMENTS
auto-ack 9 NO COMMENTS
DEFAULT un-acknowledged(1) NO COMMENTS

connPath

Type: equipment:ConnectionStatus
Primitive Type: scalar:Bitmask8
Like: equipment:Connectivity:connPath
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unknown 0 NO COMMENTS
A 1 NO COMMENTS
B 2 NO COMMENTS
DEFAULT unknown(0) NO COMMENTS

connStatus

Type: equipment:ConnectionStatus
Primitive Type: scalar:Bitmask8
Like: equipment:Connectivity:connStatus
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unknown 0 NO COMMENTS
A 1 NO COMMENTS
B 2 NO COMMENTS
DEFAULT unknown(0) NO COMMENTS

discovery

Type: equipment:Discovery
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
undiscovered 0 NO COMMENTS
in-progress 1 NO COMMENTS
malformed-fru-info 2 NO COMMENTS
fru-not-ready 3 NO COMMENTS
insufficiently-equipped 4 NO COMMENTS
invalid-adaptor-iocard 5 NO COMMENTS
failed 8 NO COMMENTS
complete 16 NO COMMENTS
retry 32 NO COMMENTS
throttled 64 NO COMMENTS
illegal-fru 128 NO COMMENTS
fru-identity-indeterminate 129 NO COMMENTS
fru-state-indeterminate 130 NO COMMENTS
DEFAULT undiscovered(0) NO COMMENTS

discoveryStatus

Type: equipment:ConnectionStatus
Primitive Type: scalar:Bitmask8
Like: equipment:Connectivity:discoveryStatus
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unknown 0 NO COMMENTS
A 1 NO COMMENTS
B 2 NO COMMENTS
DEFAULT unknown(0) NO COMMENTS

dn

Type: reference:Object
Units: null
Encrypted: false
Access: implicit
Category: TopLevelDn
Property Validators:
Comments:
The Distinguished Name (dn) unambiguously identifies an object in the system.
The dn provides a fully qualified path from the top of the object tree, all the way to the object. It is built as a sequence of relative names separated by the "/" character.
For example:
< ... dn = "sys/chassis-5/blade-2/adaptor-1" />

fabricEpDn

Type: reference:Object
Refers: fabric:ChassisEp
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS

fltAggr

Type: scalar:Uint64
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS

fsmDescr

Type: fsm:Descr
Primitive Type: string:Basic
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "256"
        Allowed Chars:
            Regex: [a-zA-Z0-9\[\]!#$%()*+,-./:;@ _{|}˜?&]+
Comments:
NO COMMENTS

fsmFlags

Type: equipment:ChassisFsmFlags
Primitive Type: scalar:Bitmask64
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
sam:dme:EquipmentChassisAssociate:disk-zoning-config 1125899906842624ull NO COMMENTS
sam:dme:EquipmentChassisAssociate:sas-expander-settings-config 16777216ull NO COMMENTS
sam:dme:EquipmentChassisAssociate:disk-activate 18014398509481984ull NO COMMENTS
sam:dme:EquipmentChassisAssociate:cmc-update 2251799813685248ull NO COMMENTS
sam:dme:EquipmentChassisAssociate:fw-update 288230376151711744ull NO COMMENTS
sam:dme:EquipmentChassisAssociate:storctrl-update 36028797018963968ull NO COMMENTS
sam:dme:EquipmentChassisAssociate:cruz-update 4503599627370496ull NO COMMENTS
sam:dme:EquipmentChassisAssociate:config-server-sioc-conn-state 524288ull NO COMMENTS
sam:dme:EquipmentChassisAssociate:cp-rename 562949953421312ull NO COMMENTS
sam:dme:EquipmentChassisDisassociate:switch-unconfig 576460752303423488ull NO COMMENTS
sam:dme:EquipmentChassisOobStorageAdminCfg:oob-storage-config 68719476736ull NO COMMENTS
sam:dme:EquipmentChassisAssociate:host-reboot 72057594037927936ull NO COMMENTS
sam:dme:EquipmentChassisAssociate:sas-update 9007199254740992ull NO COMMENTS
defaultValue 0ull NO COMMENTS

fsmPrev

Type: equipment:ChassisFsmStatus
Primitive Type: scalar:Enum32
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
nop 0u NO COMMENTS
DynamicReallocationBegin 1048u NO COMMENTS
DynamicReallocationConfig 1049u NO COMMENTS
DynamicReallocationFail 1051u NO COMMENTS
DynamicReallocationSuccess 1052u NO COMMENTS
RemoveChassisDecomission 10u NO COMMENTS
RemoveChassisDisableEndPoint 11u NO COMMENTS
RemoveChassisUnIdentifyLocal 12u NO COMMENTS
RemoveChassisUnIdentifyPeer 13u NO COMMENTS
PsuPolicyConfigBegin 140u NO COMMENTS
PsuPolicyConfigExecute 141u NO COMMENTS
RemoveChassisWait 14u NO COMMENTS
OobStorageAdminCfgBegin 1883u NO COMMENTS
OobStorageAdminCfgOobStorageConfig 1884u NO COMMENTS
RemoveChassisCleanupVnicsLocal 1905u NO COMMENTS
RemoveChassisCleanupVnicsPeer 1906u NO COMMENTS
OobStorageAdminCfgFail 1915u NO COMMENTS
OobStorageAdminCfgSuccess 1916u NO COMMENTS
OobStorageAdminCfgOobStorageInventory 2042u NO COMMENTS
AssociateBegin 2067u NO COMMENTS
AssociateDownloadImages 2068u NO COMMENTS
AssociateCopyRemote 2069u NO COMMENTS
AssociateWaitBeforeInstallation 2070u NO COMMENTS
AssociateUpdateCmc 2071u NO COMMENTS
AssociatePollUpdateCmc 2072u NO COMMENTS
AssociateUpdateAdaptor 2073u NO COMMENTS
AssociatePollUpdateAdaptor 2074u NO COMMENTS
AssociateUpdateSasExpander 2075u NO COMMENTS
AssociatePollUpdateSasExpander 2076u NO COMMENTS
AssociateActivateSasExpander 2077u NO COMMENTS
AssociatePollSasExpanderActivate 2078u NO COMMENTS
AssociateActivateCmc 2079u NO COMMENTS
AssociatePollCmcActivation 2080u NO COMMENTS
AssociatePowerOffServers 2081u NO COMMENTS
AssociateWaitForPowerOff 2082u NO COMMENTS
AssociateActivateAdaptor 2083u NO COMMENTS
AssociatePollAdaptorActivation 2084u NO COMMENTS
AssociateActivateStorageCtlr 2085u NO COMMENTS
AssociatePollStorageCtlrActivation 2086u NO COMMENTS
AssociateActivateBrdCtlr 2087u NO COMMENTS
AssociatePollBrdCtlrActivation 2088u NO COMMENTS
AssociateActivateLocalDisk 2089u NO COMMENTS
AssociatePowerOnServers 2090u NO COMMENTS
AssociateDiskZoningConfig 2091u NO COMMENTS
AssociatePostDiskZoneStorageInvCMC 2092u NO COMMENTS
AssociatePostDiskZoneStorageInvCIMC 2093u NO COMMENTS
AssociatePollPostDiskZoneStorageInvCIMC 2094u NO COMMENTS
AssociateDeleteCurlDownloadedImages 2095u NO COMMENTS
AssociateDeleteImagesRemote 2096u NO COMMENTS
AssociateUnlockFirmwareImage 2097u NO COMMENTS
DisassociateBegin 2098u NO COMMENTS
DisassociateComplete 2099u NO COMMENTS
ChassisUpgradeBegin 2115u NO COMMENTS
ChassisUpgradeUpdateRequest 2116u NO COMMENTS
ChassisUpgradePollUpdateStatus 2117u NO COMMENTS
ChassisUpgradeActivateCmc 2118u NO COMMENTS
ChassisUpgradePollCmcActivation 2119u NO COMMENTS
ChassisUpgradePowerOffServers 2120u NO COMMENTS
ChassisUpgradeWaitForPowerOff 2121u NO COMMENTS
ChassisUpgradeActivateStorageCtlr 2122u NO COMMENTS
ChassisUpgradePollStorageCtlrActivation 2123u NO COMMENTS
ChassisUpgradeActivateAdaptor 2124u NO COMMENTS
ChassisUpgradePollAdaptorActivation 2125u NO COMMENTS
ChassisUpgradeActivateBrdCtlr 2126u NO COMMENTS
ChassisUpgradePollBrdCtlrActivation 2127u NO COMMENTS
ChassisUpgradeActivateSasExpander 2128u NO COMMENTS
ChassisUpgradePollSasExpanderActivate 2129u NO COMMENTS
ChassisUpgradeResetSasExpander 2130u NO COMMENTS
ChassisUpgradeActivateLocalDisk 2131u NO COMMENTS
ChassisUpgradePollLocalDiskActivate 2132u NO COMMENTS
ChassisUpgradePowerOnServers 2133u NO COMMENTS
AssociateFail 2163u NO COMMENTS
AssociateSuccess 2164u NO COMMENTS
ChassisUpgradeFail 2165u NO COMMENTS
ChassisUpgradeSuccess 2166u NO COMMENTS
DisassociateFail 2167u NO COMMENTS
DisassociateSuccess 2168u NO COMMENTS
AssociateConfigChassisAdapterConnectivity 2246u NO COMMENTS
AssociateSasExpanderConfig 2290u NO COMMENTS
AssociatePollSasExpanderConfig 2291u NO COMMENTS
FwUpgradeBegin 2292u NO COMMENTS
FwUpgradeDownloadImages 2293u NO COMMENTS
FwUpgradeCopyRemote 2294u NO COMMENTS
FwUpgradeWaitBeforeInstallation 2295u NO COMMENTS
FwUpgradeUpdateCmc 2296u NO COMMENTS
FwUpgradePollUpdateCmc 2297u NO COMMENTS
FwUpgradeUpdateAdaptor 2298u NO COMMENTS
FwUpgradePollUpdateAdaptor 2299u NO COMMENTS
FwUpgradeUpdateSasExpander 2300u NO COMMENTS
FwUpgradePollUpdateSasExpander 2301u NO COMMENTS
FwUpgradeDeleteCurlDownloadedImages 2302u NO COMMENTS
FwUpgradeDeleteImagesRemote 2303u NO COMMENTS
FwUpgradeUnlockFirmwareImage 2304u NO COMMENTS
PowerCapWait 2305u NO COMMENTS
FwUpgradeFail 2306u NO COMMENTS
FwUpgradeSuccess 2307u NO COMMENTS
PsuPolicyConfigFail 374u NO COMMENTS
PsuPolicyConfigSuccess 375u NO COMMENTS
RemoveChassisFail 376u NO COMMENTS
RemoveChassisSuccess 377u NO COMMENTS
PowerCapBegin 643u NO COMMENTS
PowerCapConfig 644u NO COMMENTS
PowerCapFail 980u NO COMMENTS
PowerCapSuccess 981u NO COMMENTS
RemoveChassisBegin 9u NO COMMENTS
DEFAULT nop(0u) NO COMMENTS

fsmProgr

Type: fsm:Progress
Primitive Type: scalar:UByte
Units: %
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
    Range:  min: (short)0  max: (short)100
Comments:
NO COMMENTS
Constants
defaultValue 100 NO COMMENTS

fsmRmtInvErrCode

Type: condition:ErrCode
Primitive Type: scalar:Uint32
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
none 0u NO COMMENTS
ERR-MO-illegal-iterator-state 100u NO COMMENTS
ERR-MO-illegal-object-lifecycle-transition 101u NO COMMENTS
ERR-MO-object-not-found 102u NO COMMENTS
ERR-MO-duplicate-object 103u NO COMMENTS
ERR-MO-naming-rule-violation 104u NO COMMENTS
ERR-MO-illegal-creation 105u NO COMMENTS
ERR-MO-illegal-containment 106u NO COMMENTS
ERR-MO-deletion-rule-violation 107u NO COMMENTS
ERR-MO-PROPERTY-value-out-of-range 120u NO COMMENTS
ERR-MO-PROPERTY-no-such-property 121u NO COMMENTS
ERR-MO-META-no-such-object-class 122u NO COMMENTS
ERR-MO-CONFIG-child-object-cant-be-configured 130u NO COMMENTS
ERR-FILTER-illegal-format 140u NO COMMENTS
ERR-MO-resource-allocation 150u NO COMMENTS
ERR-FSM-no-such-state 160u NO COMMENTS
ERR-MO-access-denied 170u NO COMMENTS
ERR-test-error-1 501u NO COMMENTS
ERR-test-error-2 502u NO COMMENTS
ERR-HOST-fru-identity-mismatch 503u NO COMMENTS
ERR-IBMC-connect-error 504u NO COMMENTS
ERR-IBMC-fru-retrieval-error 505u NO COMMENTS
ERR-IBMC-invalid-end-point-config 506u NO COMMENTS
ERR-SWITCH-invalid-if-config 507u NO COMMENTS
ERR-DNLD-authentication-failure 508u NO COMMENTS
ERR-DNLD-invalid-image 509u NO COMMENTS
ERR-DNLD-no-space 510u NO COMMENTS
ERR-DNLD-no-file 511u NO COMMENTS
ERR-radius-group-set-error 512u NO COMMENTS
ERR-ldap-group-set-error 513u NO COMMENTS
ERR-tacacs-group-set-error 514u NO COMMENTS
ERR-tacacs-enable-error 515u NO COMMENTS
ERR-radius-set-error 516u NO COMMENTS
ERR-radius-global-set-error 517u NO COMMENTS
ERR-tacacs-set-error 518u NO COMMENTS
ERR-tacacs-global-set-error 519u NO COMMENTS
ERR-ldap-get-error 520u NO COMMENTS
ERR-ldap-delete-error 521u NO COMMENTS
ERR-ldap-set-error 522u NO COMMENTS
ERR-acct-realm-set-error 523u NO COMMENTS
ERR-auth-realm-set-error 524u NO COMMENTS
ERR-role-set-error 525u NO COMMENTS
ERR-locale-set-error 526u NO COMMENTS
ERR-user-set-error 527u NO COMMENTS
ERR-NTP-set-error 528u NO COMMENTS
ERR-NTP-get-error 529u NO COMMENTS
ERR-NTP-delete-error 530u NO COMMENTS
ERR-DNS-set-error 531u NO COMMENTS
ERR-DNS-get-error 532u NO COMMENTS
ERR-DNS-delete-error 533u NO COMMENTS
ERR-UPDATE-in-progress 534u NO COMMENTS
ERR-UPDATE-failed 535u NO COMMENTS
ERR-UPDATE-retry 536u NO COMMENTS
ERR-admin-passwd-set 537u NO COMMENTS
ERR-delete-user 538u NO COMMENTS
ERR-create-user 539u NO COMMENTS
ERR-modify-user 540u NO COMMENTS
ERR-modify-role 541u NO COMMENTS
ERR-modify-locale 542u NO COMMENTS
ERR-modify-user-role 543u NO COMMENTS
ERR-modify-user-locale 544u NO COMMENTS
ERR-HTTP-set-error 545u NO COMMENTS
ERR-HTTPS-set-error 546u NO COMMENTS
ERR-timezone-set-error 547u NO COMMENTS
ERR-set-network 548u NO COMMENTS
ERR-set-port-channel 549u NO COMMENTS
ERR-BIOS-network-boot-order-not-found 550u NO COMMENTS
ERR-authentication 551u NO COMMENTS
ERR-authorization-required 552u NO COMMENTS
ERR-user-account-expired 553u NO COMMENTS
ERR-session-cache-full 554u NO COMMENTS
ERR-session-not-found 555u NO COMMENTS
ERR-service-not-ready 556u NO COMMENTS
ERR-internal-error 557u NO COMMENTS
ERR-create-role 558u NO COMMENTS
ERR-create-locale 559u NO COMMENTS
ERR-Diagnostics-in-progress 560u NO COMMENTS
ERR-Diagnostics-memtest-in-progress 561u NO COMMENTS
ERR-Diagnostics-network-in-progress 562u NO COMMENTS
ERR-delete-role 563u NO COMMENTS
ERR-delete-locale 564u NO COMMENTS
ERR-efi-Diagnostics--in-progress 565u NO COMMENTS
ERR-delete-session 566u NO COMMENTS
ERR-DNLD-hostkey-mismatch 567u NO COMMENTS
ERR-IBMC-results-not-ready 568u NO COMMENTS
ERR-IBMC-analyze-results 569u NO COMMENTS
ERR-create-keyring 570u NO COMMENTS
ERR-insufficiently-equipped 571u NO COMMENTS
ERR-max-userid-sessions-reached 572u NO COMMENTS
ERR-set-password-strength-check 573u NO COMMENTS
ERR-BOARDCTRLUPDATE-ignore 574u NO COMMENTS
ERR-DIAG-test-failed 575u NO COMMENTS
ERR-DIAG-cancelled 576u NO COMMENTS
ERR-DIAG-fsm-restarted 577u NO COMMENTS
ERR-UNABLE-TO-FETCH-BIOS-SETTINGS 578u NO COMMENTS
ERR-BIOS-TOKENS-OLD-BIOS 579u NO COMMENTS
ERR-BIOS-TOKENS-OLD-CIMC 580u NO COMMENTS
ERR-POWER-CAP-UNSUPPORTED 581u NO COMMENTS
ERR-provider-group-set-error 582u NO COMMENTS
ERR-ldap-group-modify-error 583u NO COMMENTS
ERR-provider-group-modify-error 584u NO COMMENTS
ERR-aaa-config-modify-error 585u NO COMMENTS
ERR-get-max-http-user-sessions 586u NO COMMENTS
ERR-SERVER-mis-connect 587u NO COMMENTS
ERR-store-pre-login-banner-msg 588u NO COMMENTS
ERR-ACTIVATE-in-progress 589u NO COMMENTS
ERR-ACTIVATE-failed 590u NO COMMENTS
ERR-ACTIVATE-retry 591u NO COMMENTS
ERR-request-timeout 592u NO COMMENTS
ERR-missing-method 593u NO COMMENTS
ERR-xml-parse-error 594u NO COMMENTS
ERR-auth-issue 595u NO COMMENTS
ERR-http-initializing 596u NO COMMENTS
ERR-secondary-node 597u NO COMMENTS
ERR-auth-realm-get-error 598u NO COMMENTS
ERR-radius-get-error 599u NO COMMENTS
ERR-tacacs-plus-get-error 600u NO COMMENTS
ERR-ep-set-error 601u NO COMMENTS
ERR-MAX-subscriptions-allowed-error 602u NO COMMENTS
ERR-enable-mgmt-conn 603u NO COMMENTS
ERR-reset-adapter 604u NO COMMENTS
ERR-TOKEN-request-denied 605u NO COMMENTS
ERR-cli-session-limit-reached 606u NO COMMENTS
ERR-2fa-auth-retry 607u NO COMMENTS
ERR-IBMC-connector-info-retrieval-error 608u NO COMMENTS
ERR-create-tp 609u NO COMMENTS
ERR-POWER-PROFILE-IN-PROGRESS 610u NO COMMENTS
ERR-DNLD-usb-unmounted 611u NO COMMENTS
ERR-downgrade-fail 612u NO COMMENTS
ERR-set-min-passphrase-length 613u NO COMMENTS
ERR-set-key-cert 614u NO COMMENTS
DEFAULT 0 NO COMMENTS

fsmRmtInvErrDescr

Type: string:Basic
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "510"
Comments:
NO COMMENTS

fsmRmtInvRslt

Type: condition:RemoteInvRslt
Primitive Type: scalar:Bitmask32
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
not-applicable 0u NO COMMENTS
resource-unavailable 1024u NO COMMENTS
service-unavailable 1048576u NO COMMENTS
intermittent-error 1073741824u NO COMMENTS
sw-defect 128u NO COMMENTS
service-not-implemented-ignore 131072u NO COMMENTS
extend-timeout 134217728u NO COMMENTS
capability-not-implemented-failure 16384u NO COMMENTS
illegal-fru 16777216u NO COMMENTS
end-point-unavailable 16u NO COMMENTS
failure 1u NO COMMENTS
resource-capacity-exceeded 2048u NO COMMENTS
service-protocol-error 2097152u NO COMMENTS
fw-defect 256u NO COMMENTS
service-not-implemented-fail 262144u NO COMMENTS
task-reset 268435456u NO COMMENTS
unidentified-fail 2u NO COMMENTS
capability-not-supported 32768u NO COMMENTS
end-point-failed 32u NO COMMENTS
fru-state-indeterminate 33554432u NO COMMENTS
resource-dependency 4096u NO COMMENTS
fru-identity-indeterminate 4194304u NO COMMENTS
internal-error 4u NO COMMENTS
hw-defect 512u NO COMMENTS
service-not-supported 524288u NO COMMENTS
fru-not-supported 536870912u NO COMMENTS
end-point-protocol-error 64u NO COMMENTS
capability-unavailable 65536u NO COMMENTS
fru-not-ready 67108864u NO COMMENTS
capability-not-implemented-ignore 8192u NO COMMENTS
fru-info-malformed 8388608u NO COMMENTS
timeout 8u NO COMMENTS
DEFAULT not-applicable(0u) NO COMMENTS

fsmStageDescr

Type: fsm:Descr
Primitive Type: string:Basic
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "256"
        Allowed Chars:
            Regex: [a-zA-Z0-9\[\]!#$%()*+,-./:;@ _{|}˜?&]+
Comments:
NO COMMENTS

fsmStamp

Type: scalar:Date
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
never 0ull NO COMMENTS
DEFAULT 0 NO COMMENTS

fsmStatus

Type: equipment:ChassisFsmStatus
Primitive Type: scalar:Enum32
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
nop 0u NO COMMENTS
DynamicReallocationBegin 1048u NO COMMENTS
DynamicReallocationConfig 1049u NO COMMENTS
DynamicReallocationFail 1051u NO COMMENTS
DynamicReallocationSuccess 1052u NO COMMENTS
RemoveChassisDecomission 10u NO COMMENTS
RemoveChassisDisableEndPoint 11u NO COMMENTS
RemoveChassisUnIdentifyLocal 12u NO COMMENTS
RemoveChassisUnIdentifyPeer 13u NO COMMENTS
PsuPolicyConfigBegin 140u NO COMMENTS
PsuPolicyConfigExecute 141u NO COMMENTS
RemoveChassisWait 14u NO COMMENTS
OobStorageAdminCfgBegin 1883u NO COMMENTS
OobStorageAdminCfgOobStorageConfig 1884u NO COMMENTS
RemoveChassisCleanupVnicsLocal 1905u NO COMMENTS
RemoveChassisCleanupVnicsPeer 1906u NO COMMENTS
OobStorageAdminCfgFail 1915u NO COMMENTS
OobStorageAdminCfgSuccess 1916u NO COMMENTS
OobStorageAdminCfgOobStorageInventory 2042u NO COMMENTS
AssociateBegin 2067u NO COMMENTS
AssociateDownloadImages 2068u NO COMMENTS
AssociateCopyRemote 2069u NO COMMENTS
AssociateWaitBeforeInstallation 2070u NO COMMENTS
AssociateUpdateCmc 2071u NO COMMENTS
AssociatePollUpdateCmc 2072u NO COMMENTS
AssociateUpdateAdaptor 2073u NO COMMENTS
AssociatePollUpdateAdaptor 2074u NO COMMENTS
AssociateUpdateSasExpander 2075u NO COMMENTS
AssociatePollUpdateSasExpander 2076u NO COMMENTS
AssociateActivateSasExpander 2077u NO COMMENTS
AssociatePollSasExpanderActivate 2078u NO COMMENTS
AssociateActivateCmc 2079u NO COMMENTS
AssociatePollCmcActivation 2080u NO COMMENTS
AssociatePowerOffServers 2081u NO COMMENTS
AssociateWaitForPowerOff 2082u NO COMMENTS
AssociateActivateAdaptor 2083u NO COMMENTS
AssociatePollAdaptorActivation 2084u NO COMMENTS
AssociateActivateStorageCtlr 2085u NO COMMENTS
AssociatePollStorageCtlrActivation 2086u NO COMMENTS
AssociateActivateBrdCtlr 2087u NO COMMENTS
AssociatePollBrdCtlrActivation 2088u NO COMMENTS
AssociateActivateLocalDisk 2089u NO COMMENTS
AssociatePowerOnServers 2090u NO COMMENTS
AssociateDiskZoningConfig 2091u NO COMMENTS
AssociatePostDiskZoneStorageInvCMC 2092u NO COMMENTS
AssociatePostDiskZoneStorageInvCIMC 2093u NO COMMENTS
AssociatePollPostDiskZoneStorageInvCIMC 2094u NO COMMENTS
AssociateDeleteCurlDownloadedImages 2095u NO COMMENTS
AssociateDeleteImagesRemote 2096u NO COMMENTS
AssociateUnlockFirmwareImage 2097u NO COMMENTS
DisassociateBegin 2098u NO COMMENTS
DisassociateComplete 2099u NO COMMENTS
ChassisUpgradeBegin 2115u NO COMMENTS
ChassisUpgradeUpdateRequest 2116u NO COMMENTS
ChassisUpgradePollUpdateStatus 2117u NO COMMENTS
ChassisUpgradeActivateCmc 2118u NO COMMENTS
ChassisUpgradePollCmcActivation 2119u NO COMMENTS
ChassisUpgradePowerOffServers 2120u NO COMMENTS
ChassisUpgradeWaitForPowerOff 2121u NO COMMENTS
ChassisUpgradeActivateStorageCtlr 2122u NO COMMENTS
ChassisUpgradePollStorageCtlrActivation 2123u NO COMMENTS
ChassisUpgradeActivateAdaptor 2124u NO COMMENTS
ChassisUpgradePollAdaptorActivation 2125u NO COMMENTS
ChassisUpgradeActivateBrdCtlr 2126u NO COMMENTS
ChassisUpgradePollBrdCtlrActivation 2127u NO COMMENTS
ChassisUpgradeActivateSasExpander 2128u NO COMMENTS
ChassisUpgradePollSasExpanderActivate 2129u NO COMMENTS
ChassisUpgradeResetSasExpander 2130u NO COMMENTS
ChassisUpgradeActivateLocalDisk 2131u NO COMMENTS
ChassisUpgradePollLocalDiskActivate 2132u NO COMMENTS
ChassisUpgradePowerOnServers 2133u NO COMMENTS
AssociateFail 2163u NO COMMENTS
AssociateSuccess 2164u NO COMMENTS
ChassisUpgradeFail 2165u NO COMMENTS
ChassisUpgradeSuccess 2166u NO COMMENTS
DisassociateFail 2167u NO COMMENTS
DisassociateSuccess 2168u NO COMMENTS
AssociateConfigChassisAdapterConnectivity 2246u NO COMMENTS
AssociateSasExpanderConfig 2290u NO COMMENTS
AssociatePollSasExpanderConfig 2291u NO COMMENTS
FwUpgradeBegin 2292u NO COMMENTS
FwUpgradeDownloadImages 2293u NO COMMENTS
FwUpgradeCopyRemote 2294u NO COMMENTS
FwUpgradeWaitBeforeInstallation 2295u NO COMMENTS
FwUpgradeUpdateCmc 2296u NO COMMENTS
FwUpgradePollUpdateCmc 2297u NO COMMENTS
FwUpgradeUpdateAdaptor 2298u NO COMMENTS
FwUpgradePollUpdateAdaptor 2299u NO COMMENTS
FwUpgradeUpdateSasExpander 2300u NO COMMENTS
FwUpgradePollUpdateSasExpander 2301u NO COMMENTS
FwUpgradeDeleteCurlDownloadedImages 2302u NO COMMENTS
FwUpgradeDeleteImagesRemote 2303u NO COMMENTS
FwUpgradeUnlockFirmwareImage 2304u NO COMMENTS
PowerCapWait 2305u NO COMMENTS
FwUpgradeFail 2306u NO COMMENTS
FwUpgradeSuccess 2307u NO COMMENTS
PsuPolicyConfigFail 374u NO COMMENTS
PsuPolicyConfigSuccess 375u NO COMMENTS
RemoveChassisFail 376u NO COMMENTS
RemoveChassisSuccess 377u NO COMMENTS
PowerCapBegin 643u NO COMMENTS
PowerCapConfig 644u NO COMMENTS
PowerCapFail 980u NO COMMENTS
PowerCapSuccess 981u NO COMMENTS
RemoveChassisBegin 9u NO COMMENTS
DEFAULT nop(0u) NO COMMENTS

fsmTry

Type: scalar:UByte
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS

id

Type: equipment:Id
Primitive Type: scalar:Uint32
Overrides:equipment:Item:id
Units: null
Encrypted: false
Naming Property -- [NAMING RULES]
Access: naming
Category: TopLevelRegular
Property Validators:
    Range:  min: (long)1l  max: (long)255l
Comments:
NO COMMENTS

lcTs

Type: scalar:Date
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
life cycle timestamp used for internal purposes

licGP

Type: license:GracePeriod
Primitive Type: scalar:Uint64
Like: license:Licensable:licGP
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS

licState

Type: license:State
Primitive Type: scalar:Enum8
Like: license:Licensable:licState
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unknown 0 NO COMMENTS
license-ok 1 NO COMMENTS
license-insufficient 2 NO COMMENTS
license-graceperiod 3 NO COMMENTS
license-expired 4 NO COMMENTS
not-applicable 5 NO COMMENTS
DEFAULT unknown(0) NO COMMENTS

managingInst

Type: network:SwitchId
Primitive Type: scalar:Enum8
Like: equipment:Connectivity:managingInst
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
NONE 0 NO COMMENTS
A 1 NO COMMENTS
B 2 NO COMMENTS
DEFAULT A(1) NO COMMENTS

mfgTime

Type: scalar:Date
Like: equipment:MfgInfo:mfgTime
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
not-applicable 0ull NO COMMENTS
DEFAULT not-applicable(0ull) NO COMMENTS

model

Type: equipment:Model
Primitive Type: string:Basic
Like: equipment:Info:model
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "510"
Comments:
NO COMMENTS

operQualifier

Type: equipment:ChassisIssues
Primitive Type: scalar:Bitmask64
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
not-applicable 0ull NO COMMENTS
psu-voltage 1024ull NO COMMENTS
iocard-voltage 1048576ull NO COMMENTS
fabric-unsupported-conn 1073741824ull NO COMMENTS
chassis-post-failure 128ull NO COMMENTS
fan-power 131072ull NO COMMENTS
compute-power 134217728ull NO COMMENTS
fan-inoperable 16384ull NO COMMENTS
compute-inoperable 16777216ull NO COMMENTS
chassis-power 16ull NO COMMENTS
chassis-unsupported 17179869184ull NO COMMENTS
chassis-thermal 1ull NO COMMENTS
psu-perf 2048ull NO COMMENTS
iocard-perf 2097152ull NO COMMENTS
chassis-limit-exceeded 2147483648ull NO COMMENTS
psu-thermal 256ull NO COMMENTS
iocard-thermal 262144ull NO COMMENTS
iocard-inaccessible 268435456ull NO COMMENTS
chassis-inoperable 2ull NO COMMENTS
fan-voltage 32768ull NO COMMENTS
removed 32ull NO COMMENTS
compute-voltage 33554432ull NO COMMENTS
backplane-port-problem 34359738368ull NO COMMENTS
psu-power 4096ull NO COMMENTS
iocard-power 4194304ull NO COMMENTS
chassis-vif-capacity-reduced 4294967296ull const name="hba-perf" value="2147483648"/>
chassis-voltage 4ull NO COMMENTS
psu-inoperable 512ull NO COMMENTS
iocard-inoperable 524288ull NO COMMENTS
fabric-conn-problem 536870912ull NO COMMENTS
config 64ull NO COMMENTS
fan-perf 65536ull NO COMMENTS
compute-perf 67108864ull NO COMMENTS
fan-thermal 8192ull NO COMMENTS
compute-thermal 8388608ull NO COMMENTS
chassis-port-channel-enabled 8589934592ull NO COMMENTS
chassis-perf 8ull NO COMMENTS
DEFAULT not-applicable(0ull) NO COMMENTS

operQualifierReason

Type: equipment:OperQualifierReason
Primitive Type: string:Basic
Like: equipment:StatefulIf:operQualifierReason
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "256"
        Allowed Chars:
            Regex: [a-zA-Z0-9\[\]!#$%()*+,-./:;@ _{|}˜?&]+
Comments:
NO COMMENTS
Constants
defaultValue "N/A" NO COMMENTS

operState

Type: equipment:Operability
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unknown 0 NO COMMENTS
operable 1 NO COMMENTS
inoperable 2 NO COMMENTS
degraded 3 NO COMMENTS
powered-off 4 NO COMMENTS
power-problem 5 NO COMMENTS
removed 6 NO COMMENTS
voltage-problem 7 NO COMMENTS
thermal-problem 8 NO COMMENTS
performance-problem 9 NO COMMENTS
accessibility-problem 10 NO COMMENTS
identity-unestablishable 11 NO COMMENTS
bios-post-timeout 12 NO COMMENTS
disabled 13 NO COMMENTS
malformed-fru 14 NO COMMENTS
backplane-port-problem 15 NO COMMENTS
chassis-intrusion 16 NO COMMENTS
non-optimal 17 NO COMMENTS
unsupported-config 18 NO COMMENTS
fabric-conn-problem 51 NO COMMENTS
fabric-unsupported-conn 52 NO COMMENTS
config 81 NO COMMENTS
equipment-problem 82 NO COMMENTS
decomissioning 83 NO COMMENTS
chassis-limit-exceeded 84 NO COMMENTS
not-supported 100 NO COMMENTS
discovery 101 NO COMMENTS
discovery-failed 102 NO COMMENTS
identify 103 NO COMMENTS
post-failure 104 NO COMMENTS
upgrade-problem 105 NO COMMENTS
peer-comm-problem 106 NO COMMENTS
auto-upgrade 107 NO COMMENTS
link-activate-blocked 108 NO COMMENTS
DEFAULT unknown(0) NO COMMENTS

operability

Type: equipment:Operability
Primitive Type: scalar:Enum8
Like: equipment:StatefulIf:operability
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unknown 0 NO COMMENTS
operable 1 NO COMMENTS
inoperable 2 NO COMMENTS
degraded 3 NO COMMENTS
powered-off 4 NO COMMENTS
power-problem 5 NO COMMENTS
removed 6 NO COMMENTS
voltage-problem 7 NO COMMENTS
thermal-problem 8 NO COMMENTS
performance-problem 9 NO COMMENTS
accessibility-problem 10 NO COMMENTS
identity-unestablishable 11 NO COMMENTS
bios-post-timeout 12 NO COMMENTS
disabled 13 NO COMMENTS
malformed-fru 14 NO COMMENTS
backplane-port-problem 15 NO COMMENTS
chassis-intrusion 16 NO COMMENTS
non-optimal 17 NO COMMENTS
unsupported-config 18 NO COMMENTS
fabric-conn-problem 51 NO COMMENTS
fabric-unsupported-conn 52 NO COMMENTS
config 81 NO COMMENTS
equipment-problem 82 NO COMMENTS
decomissioning 83 NO COMMENTS
chassis-limit-exceeded 84 NO COMMENTS
not-supported 100 NO COMMENTS
discovery 101 NO COMMENTS
discovery-failed 102 NO COMMENTS
identify 103 NO COMMENTS
post-failure 104 NO COMMENTS
upgrade-problem 105 NO COMMENTS
peer-comm-problem 106 NO COMMENTS
auto-upgrade 107 NO COMMENTS
link-activate-blocked 108 NO COMMENTS
DEFAULT unknown(0) NO COMMENTS

partNumber

Type: equipment:PartNumber
Primitive Type: string:Basic
Like: equipment:FruidInfo:partNumber
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "510"
Comments:
NO COMMENTS

power

Type: equipment:ChassisPowerOperState
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unknown 0 NO COMMENTS
ok 1 NO COMMENTS
failed 2 NO COMMENTS
input-failed 3 NO COMMENTS
input-degraded 4 NO COMMENTS
output-failed 5 NO COMMENTS
output-degraded 6 NO COMMENTS
redundancy-failed 7 NO COMMENTS
redundancy-degraded 8 NO COMMENTS
DEFAULT unknown(0) NO COMMENTS

presence

Type: equipment:Presence
Primitive Type: scalar:Enum8
Like: equipment:StatefulIf:presence
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unknown 0 NO COMMENTS
empty 1 NO COMMENTS
equipped 10 NO COMMENTS
missing 11 NO COMMENTS
mismatch 12 NO COMMENTS
equipped-not-primary 13 NO COMMENTS
equipped-slave 14 NO COMMENTS
mismatch-slave 15 NO COMMENTS
missing-slave 16 NO COMMENTS
equipped-identity-unestablishable 20 NO COMMENTS
mismatch-identity-unestablishable 21 NO COMMENTS
equipped-with-malformed-fru 22 NO COMMENTS
inaccessible 30 NO COMMENTS
unauthorized 40 NO COMMENTS
not-supported 100 NO COMMENTS
equipped-unsupported 101 NO COMMENTS
equipped-deprecated 102 NO COMMENTS
equipped-disc-not-started 102 NO COMMENTS
equipped-disc-in-progress 103 NO COMMENTS
equipped-disc-error 104 NO COMMENTS
equipped-disc-unknown 105 NO COMMENTS
DEFAULT unknown(0) NO COMMENTS

revision

Type: equipment:Revision
Primitive Type: string:Basic
Like: equipment:Info:revision
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "510"
Comments:
NO COMMENTS
Constants
defaultValue "0" NO COMMENTS

rn

Type: reference:RN
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRn
Property Validators:
Comments:
The Relative Name (rn) uniquely identifies an object within a given context.
Note that a dn is comprised of a sequence of relative names. For example, the context "sys/chassis-1/blade-1/adaptor-1/host-eth-2" can be thought of as the following expression:
dn = <root object>/{rn}/{rn}/{rn}/{rn}/{rn}.
The rn can then be used to identify the object (for instance, "adaptor-1") within the context:
<... rn ="../" />

sacl

Type: mo:InstSaclType
Primitive Type: scalar:Bitmask8
Units: null
Encrypted: false
Access: implicit
Category: TopLevelSacl
Property Validators:
Comments:
The system acl property for each Managed Object. br/> This property is a 8 bit mask and supports the following values :-
a: del
b: mod
c: addchild
d: cascade

By default all Managed Objects have the following permissions
a: del
b: mod
c: addchild
This property is persisted in the db. If this property has a value none
it means, the user has read only permissions on this object.
Constants
none 0 NO COMMENTS
del 1 NO COMMENTS
mod 2 NO COMMENTS
addchild 4 NO COMMENTS
cascade 8 NO COMMENTS
DEFAULT 0 NO COMMENTS

seepromOperState

Type: equipment:Operability
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unknown 0 NO COMMENTS
operable 1 NO COMMENTS
inoperable 2 NO COMMENTS
degraded 3 NO COMMENTS
powered-off 4 NO COMMENTS
power-problem 5 NO COMMENTS
removed 6 NO COMMENTS
voltage-problem 7 NO COMMENTS
thermal-problem 8 NO COMMENTS
performance-problem 9 NO COMMENTS
accessibility-problem 10 NO COMMENTS
identity-unestablishable 11 NO COMMENTS
bios-post-timeout 12 NO COMMENTS
disabled 13 NO COMMENTS
malformed-fru 14 NO COMMENTS
backplane-port-problem 15 NO COMMENTS
chassis-intrusion 16 NO COMMENTS
non-optimal 17 NO COMMENTS
unsupported-config 18 NO COMMENTS
fabric-conn-problem 51 NO COMMENTS
fabric-unsupported-conn 52 NO COMMENTS
config 81 NO COMMENTS
equipment-problem 82 NO COMMENTS
decomissioning 83 NO COMMENTS
chassis-limit-exceeded 84 NO COMMENTS
not-supported 100 NO COMMENTS
discovery 101 NO COMMENTS
discovery-failed 102 NO COMMENTS
identify 103 NO COMMENTS
post-failure 104 NO COMMENTS
upgrade-problem 105 NO COMMENTS
peer-comm-problem 106 NO COMMENTS
auto-upgrade 107 NO COMMENTS
link-activate-blocked 108 NO COMMENTS
DEFAULT unknown(0) NO COMMENTS

serial

Type: equipment:Serial
Primitive Type: string:Basic
Like: equipment:Info:serial
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "510"
Comments:
NO COMMENTS

serviceState

Type: equipment:ServiceState
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
in-service 1 Indicates the server has been successfully discovered and is in service
out-of-service 2 Indicates the server has been decommissionned
in-maintenance 3 Indicates the server is in maintenance mode
DEFAULT in-service(1) Indicates the server has been successfully discovered and is in service

status

Type: mo:ModificationStatus
Primitive Type: scalar:Bitmask32
Units: null
Encrypted: false
Access: implicit
Category: TopLevelStatus
Property Validators:
Comments:
This property controls the life cycle of a managed object
Constants
removed 16u In a setter method: specifies that an object should be removed.
In the return value of a setter method: indicates that an object has been removed.
created 2u In a setter method: specifies that an object should be created. An error is returned if the object already exists.
In the return value of a setter method: indicates that an object has been created.
modified 4u In a setter method: specifies that an object should be modified
In the return value of a setter method: indicates that an object has been modified.
deleted 8u In a setter method: specifies that an object should be deleted.
In the return value of a setter method: indicates that an object has been deleted.
DEFAULT 0 This type controls the life cycle of objects passed in the XML API.

When used in a setter method (such as configConfMo), the ModificationStatus specifies whether an object should be created, modified, deleted or removed.
In the return value of a setter method, the ModificationStatus indicates the actual operation that was performed. For example, the ModificationStatus is set to "created" if the object was created. The ModificationStatus is not set if the object was neither created, modified, deleted or removed.

When invoking a setter method, the ModificationStatus is optional:
If a setter method such as configConfMo is invoked and the ModificationStatus is not set, the system automatically determines if the object should be created or modified.


thermal

Type: equipment:SensorThresholdStatus
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
unknown 0 NO COMMENTS
ok 1 NO COMMENTS
upper-non-recoverable 2 NO COMMENTS
upper-critical 3 NO COMMENTS
upper-non-critical 4 NO COMMENTS
lower-non-critical 5 NO COMMENTS
lower-critical 6 NO COMMENTS
lower-non-recoverable 7 NO COMMENTS
not-supported 100 NO COMMENTS
DEFAULT unknown(0) NO COMMENTS

thermalStateQualifier

Type: string:Basic
Units: null
Encrypted: false
Access: oper
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "510"
Comments:
NO COMMENTS

usrLbl

Type: naming:UserLabel
Primitive Type: string:Basic
Units: null
Encrypted: false
Access: admin
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "32"
        Allowed Chars:
            Regex: [a-zA-Z0-9\[\]!#$%()*+,-./:;@ _{|}˜?&]+
Comments:
Field to hold user label CSCta06454, CSCsx53838

vendor

Type: equipment:Vendor
Primitive Type: string:Basic
Like: equipment:Info:vendor
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "510"
Comments:
NO COMMENTS

versionHolder

Type: scalar:Bool
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
NO COMMENTS
Constants
yes true NO COMMENTS
no false NO COMMENTS

vid

Type: string:Basic
Like: equipment:FruidInfo:vid
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "510"
Comments:
NO COMMENTS