Class top:System (CONCRETE)

Class ID:3
Encrypted: false - Exportable: true - Persistent: true
Privileges: [admin, ext-lan-config]
SNMP OID: .1.3.6.1.4.1.9.9.719.1.127.6

Provides general information about this system, such as the name, IP address and current time.


Naming Rules
RN FORMAT: sys

    [1] PREFIX=sys


DN FORMAT: 

[0] sys

                



Containers Hierarchies
top:Root This class represents the root element in the object hierarchy. All managed objects in the system are descendants of the Root element.
 ├
top:System


Contained Hierarchy
top:System
 ├
aaa:Ep AAA End points that a user can configure (Radius, Tacacs+, LDAP)
 
 ├
aaa:EpFsm
 
 
 ├
aaa:EpFsmStage
 
 ├
aaa:EpFsmTask
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
aaa:Realm AAA configuration to set which AAA service to use
 
 ├
aaa:RealmFsm
 
 
 ├
aaa:RealmFsmStage
 
 ├
aaa:RealmFsmTask
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
aaa:SessionInfoTable
 
 ├
aaa:SessionInfo
 ├
aaa:UserEp
 
 ├
aaa:EpLogin
 
 ├
aaa:ExtMgmtCutThruTkn
 
 ├
aaa:Locale This MO represents a Locale, which can be used to restrict access to specific orgs in the org hierarchy. A Locale can be assigned to local user, remote user, ldap groups to restrict access to specific orgs. Each locale can contain a set of aaa:Org objects, which represent the set of Orgs that can be accessed when the Locale is assigned to a user.
 
 
 ├
aaa:Org Represents an org membership within a aaa:Locale object.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
aaa:PreLoginBanner
 
 ├
aaa:PwdProfile This MO stores informaion about password constratints applicable to all the local users.
 
 ├
aaa:RemoteUser
 
 
 ├
aaa:CimcSession
 
 
 ├
aaa:Session Represents an authenticated XML API or CLI session to UCS Manager. UCS Manager automatically creates a aaa:Session object when a user provides valid credentials through the XML API or CLI. The aaa:Session object is automatically deleted when the user logs out, or after a session timeout has occured.
 
 
 ├
aaa:UserLocale This MO is used to assign a locale to local user, remote user, ldap groups. This is used to restrict an user's access to certain orgs.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
aaa:UserRole This MO is used to assign a role to local user, remote user, ldap groups. This is used to manage access permission to an user.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
aaa:Role This MO is used to manage a role which can be assigned to local user, remote user, ldap groups to control access for an user.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
aaa:ShellLogin Represents a successful User Login session from a shell
 
 ├
aaa:User
 
 
 ├
aaa:CimcSession
 
 
 ├
aaa:Session Represents an authenticated XML API or CLI session to UCS Manager. UCS Manager automatically creates a aaa:Session object when a user provides valid credentials through the XML API or CLI. The aaa:Session object is automatically deleted when the user logs out, or after a session timeout has occured.
 
 
 ├
aaa:SshAuth
 
 
 ├
aaa:UserData Do not taking backup of this MO, this user data become invalid with time
 
 
 ├
aaa:UserLocale This MO is used to assign a locale to local user, remote user, ldap groups. This is used to restrict an user's access to certain orgs.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
aaa:UserRole This MO is used to assign a role to local user, remote user, ldap groups. This is used to manage access permission to an user.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
aaa:UserEpFsm
 
 
 ├
aaa:UserEpFsmStage
 
 ├
aaa:UserEpFsmTask
 
 ├
aaa:WebLogin Represents a successful User Login session through HTTP or HTTPS
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
comm:SvcEp Service configuration for various services
 
 ├
comm:CimcWebService
 
 ├
comm:Cimxml
 
 ├
comm:DateTime Object to hold system date/time information
 
 
 ├
comm:NtpProvider
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
comm:Dns Specifies the DNS domain name of this UCS system.
 
 
 ├
comm:DnsProvider
 
 ├
comm:EvtChannel
 
 ├
comm:Http
 
 ├
comm:Https
 
 ├
comm:ShellSvcLimits
 
 ├
comm:SmashCLP
 
 ├
comm:Snmp
 
 
 ├
comm:SnmpTrap
 
 
 ├
comm:SnmpUser
 
 
 
 ├
aaa:CimcSession
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
comm:Ssh Ssh MO is not user modifiable, so no access is defined However, it must be present in the model for iptables to allow the port
 
 ├
comm:SvcEpFsm
 
 
 ├
comm:SvcEpFsmStage
 
 ├
comm:SvcEpFsmTask
 
 ├
comm:Syslog
 
 
 ├
comm:SyslogClient This object is used to control how syslog messages are sent to a remote destinations
 
 
 ├
comm:SyslogConsole
 
 
 ├
comm:SyslogFile
 
 
 ├
comm:SyslogMonitor
 
 
 ├
comm:SyslogSource
 
 ├
comm:Telnet
 
 ├
comm:WebChannel
 
 ├
comm:WebSvcLimits
 
 ├
comm:Wsman
 
 ├
comm:XmlClConnPolicy
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
compute:RackUnit A physical compute RackUnit. Physical compute item representing a Rack mountable unit.

Skipping contained mo's. Too many contained mo's: 56
 ├
controller:HaController
 
 ├
controller:OperationalVersionHolder
 
 ├
controller:PreferedVersionHolder
 ├
controller:MgmtDbCheckPol
 ├
domain:FeatureCont Abstraction of domain features. Serves as a top level container for category features like serverFeatures, nwFeatures for a ucs domain.
 
 ├
domain:Feature Abstraction of domain features. Serves as a superclass of category features like serverFeature, nwFeature for a ucs domain.
 
 
 ├
domain:Parameter Parameters to put more information to a feature
 ├
equipment:Chassis A physical unit that can accomodate multiple blade servers. For example, the Cisco UCS 5108 Blade Server Chassis is six rack units (6RU) high, can mount in an industry-standard 19-inch rack and uses front-to-back cooling.
 
 ├
compute:Blade A physical compute blade. Physical compute item in blade form factor.

Skipping contained mo's. Too many contained mo's: 57
 
 ├
compute:BoardController Managed object representing a blade PLD such as CPLD, EPLD, and FPGAs for sanfrancisco blade.
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
compute:Cartridge A physical compute cartridge.
 
 
 ├
compute:ServerUnit A server instance on a cartridge.

Skipping contained mo's. Too many contained mo's: 53
 
 ├
compute:PsuControl
 
 ├
equipment:ChassisFsm
 
 
 ├
equipment:ChassisFsmStage
 
 ├
equipment:ChassisFsmTask
 
 ├
equipment:ChassisStats
 
 
 ├
equipment:ChassisStatsHist
 
 ├
equipment:ComputeConn
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
equipment:FanModule Represents an inventoried Fan module. This object is created implicitly when a Fan module is detected during equipment discovery.
 
 
 ├
equipment:Fan Represents a fan in a Fan module.
 
 
 
 ├
equipment:FanStats
 
 
 
 
 ├
equipment:FanStatsHist
 
 
 
 ├
equipment:NetworkElementFanStats
 
 
 
 
 ├
equipment:NetworkElementFanStatsHist
 
 
 
 ├
equipment:RackUnitFanStats
 
 
 
 
 ├
equipment:RackUnitFanStatsHist
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
equipment:FanModuleStats
 
 
 
 ├
equipment:FanModuleStatsHist
 
 
 ├
equipment:Led
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
equipment:IOCard Represents an inventoried IO Card on a device, such as an IO module on a UCS chassis or FEX. This object is created implicitly when an IO Card is detected during hardware discovery.
 
 
 ├
equipment:IOCardBaseFsm
 
 
 
 ├
equipment:IOCardBaseFsmStage
 
 
 ├
equipment:IOCardBaseFsmTask
 
 
 ├
equipment:IOCardFsm
 
 
 
 ├
equipment:IOCardFsmStage
 
 
 ├
equipment:IOCardFsmTask
 
 
 ├
equipment:IOCardStats
 
 
 
 ├
equipment:IOCardStatsHist
 
 
 ├
equipment:Led
 
 
 ├
equipment:POST
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
fault:SuppressTask
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
trig:LocalSched A locally defined user-defined schedule. The schedule is contained locally by the Managed Object that needs the schedule, as opposed to being referred by name.
 
 
 
 
 ├
trig:SchedWindow Scheduled Window.
 
 
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 ├
port:Group A collection of physical ports on a device. A port group is created implicitly during device discovery of IO devices such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis. All the ports in a portGroup have the same type (i.e. FC, Ethernet).
 
 
 
 ├
ether:ServerIntFIoPc
 
 
 
 
 ├
ether:ServerIntFIoPcEp
 
 
 
 ├
ether:SwitchIntFIoPc
 
 
 
 
 ├
ether:NiErrStats
 
 
 
 
 
 ├
ether:NiErrStatsHist
 
 
 
 
 ├
ether:SwitchIntFIoPcEp
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
port:IntFIo Abstraction of a physical port on an IO Card.
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 ├
network:IfStats
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 ├
port:PIoFsmTask
 
 
 
 ├
port:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 
 ├
network:IfStats
 
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 
 ├
port:PIoFsmTask
 
 ├
equipment:Led
 
 ├
equipment:Poolable
 
 
 ├
equipment:PoolPolicyRef Reference to pooling policy that caused the equipment to be added to pool.
 
 ├
equipment:Psu Represents an inventoried Power Supply Unit. This object is created implicitly when a Power Supply Unit is detected during equipment discovery.
 
 
 ├
equipment:FexPsuInputStats
 
 
 
 ├
equipment:FexPsuInputStatsHist
 
 
 ├
equipment:Led
 
 
 ├
equipment:PsuFsm
 
 
 
 ├
equipment:PsuFsmStage
 
 
 ├
equipment:PsuFsmTask
 
 
 ├
equipment:PsuInputStats Mike asked me to create a new object for the PSU input stats.
 
 
 
 ├
equipment:PsuInputStatsHist
 
 
 ├
equipment:PsuOutputStats
 
 
 
 ├
equipment:PsuOutputStatsHist
 
 
 ├
equipment:PsuStats
 
 
 
 ├
equipment:PsuStatsHist
 
 
 ├
equipment:RackUnitPsuStats
 
 
 
 ├
equipment:RackUnitPsuStatsHist
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 ├
equipment:SharedIOModule Represents an inventoried Shared IO Module on a device
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 ├
port:Group A collection of physical ports on a device. A port group is created implicitly during device discovery of IO devices such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis. All the ports in a portGroup have the same type (i.e. FC, Ethernet).
 
 
 
 ├
ether:ServerIntFIoPc
 
 
 
 
 ├
ether:ServerIntFIoPcEp
 
 
 
 ├
ether:SwitchIntFIoPc
 
 
 
 
 ├
ether:NiErrStats
 
 
 
 
 
 ├
ether:NiErrStatsHist
 
 
 
 
 ├
ether:SwitchIntFIoPcEp
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
port:IntFIo Abstraction of a physical port on an IO Card.
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 ├
network:IfStats
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 ├
port:PIoFsmTask
 
 
 
 ├
port:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 
 ├
network:IfStats
 
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 
 ├
port:PIoFsmTask
 
 ├
equipment:SwitchIOCard Represents an inventoried FI-IOM Card on a UCS-Mini Chassis This object is created implicitly when an FI-IOM Card is detected during hardware discovery. TODO: This is model similar to IOCard currently however this does not behave like a IOCard (IOM) and some of the properties will be removed if not needed.
 
 
 ├
equipment:IOCardBaseFsm
 
 
 
 ├
equipment:IOCardBaseFsmStage
 
 
 ├
equipment:IOCardBaseFsmTask
 
 
 ├
equipment:IOCardStats
 
 
 
 ├
equipment:IOCardStatsHist
 
 
 ├
equipment:SwitchIOCardFsm
 
 
 
 ├
equipment:SwitchIOCardFsmStage
 
 
 ├
equipment:SwitchIOCardFsmTask
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 ├
port:Group A collection of physical ports on a device. A port group is created implicitly during device discovery of IO devices such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis. All the ports in a portGroup have the same type (i.e. FC, Ethernet).
 
 
 
 ├
ether:ServerIntFIoPc
 
 
 
 
 ├
ether:ServerIntFIoPcEp
 
 
 
 ├
ether:SwitchIntFIoPc
 
 
 
 
 ├
ether:NiErrStats
 
 
 
 
 
 ├
ether:NiErrStatsHist
 
 
 
 
 ├
ether:SwitchIntFIoPcEp
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
port:IntFIo Abstraction of a physical port on an IO Card.
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 ├
network:IfStats
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 ├
port:PIoFsmTask
 
 
 
 ├
port:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 
 ├
network:IfStats
 
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 
 ├
port:PIoFsmTask
 
 ├
equipment:SystemIOController Represents a SIOC on a Colusa 2 chassis
 
 
 ├
compute:BoardController Managed object representing a blade PLD such as CPLD, EPLD, and FPGAs for sanfrancisco blade.
 
 
 
 ├
mgmt:Controller Controller
 
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fabric:Locale
 
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 
 ├
mgmt:Connection
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 
 ├
mgmt:Interface
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 ├
equipment:SharedIOModule Represents an inventoried Shared IO Module on a device
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Controller Controller
 
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fabric:Locale
 
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 
 ├
mgmt:Connection
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 
 ├
mgmt:Interface
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 
 ├
port:Group A collection of physical ports on a device. A port group is created implicitly during device discovery of IO devices such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis. All the ports in a portGroup have the same type (i.e. FC, Ethernet).
 
 
 
 
 ├
ether:ServerIntFIoPc
 
 
 
 
 
 ├
ether:ServerIntFIoPcEp
 
 
 
 
 ├
ether:SwitchIntFIoPc
 
 
 
 
 
 ├
ether:NiErrStats
 
 
 
 
 
 
 ├
ether:NiErrStatsHist
 
 
 
 
 
 ├
ether:SwitchIntFIoPcEp
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
port:IntFIo Abstraction of a physical port on an IO Card.
 
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 
 ├
network:IfStats
 
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 
 ├
port:PIoFsmTask
 
 
 
 
 ├
port:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 
 
 ├
network:IfStats
 
 
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 
 
 ├
port:PIoFsmTask
 
 
 ├
equipment:SiocTempStats
 
 
 
 ├
equipment:SiocTempStatsHist
 
 
 ├
equipment:SystemIOControllerFsm
 
 
 
 ├
equipment:SystemIOControllerFsmStage
 
 
 ├
equipment:SystemIOControllerFsmTask
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
event:Inst
 
 ├
fabric:Locale
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Cmclan
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 ├
sw:Ulan
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 ├
fabric:Path
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:PathConn
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fabric:PathEp
 
 
 
 
 ├
port:TrustMode
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
fault:SuppressTask
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
trig:LocalSched A locally defined user-defined schedule. The schedule is contained locally by the Managed Object that needs the schedule, as opposed to being referred by name.
 
 
 
 ├
trig:SchedWindow Scheduled Window.
 
 ├
firmware:Activity
 
 ├
firmware:ActivityTrigger
 
 ├
firmware:ImageLock
 
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:Controller Controller
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 ├
event:Inst
 
 
 ├
fabric:Locale
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:Path
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 ├
mgmt:Connection
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ControllerFsm
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 ├
mgmt:ControllerFsmTask
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 ├
dhcp:Acquired
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 ├
mgmt:IfFsmTask
 
 
 ├
mgmt:Interface
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:KvmCertificate
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
power:Budget Define chassis budget, extend it to include minimum consumption level The FSM properties to deploy chassis budget will also be contained here
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
power:ProfiledPower Power consumption limit of servers from profiling or catalog
 
 ├
ses:Enclosure
 
 
 ├
ses:DiskSlotEp
 
 ├
storage:Controller
 
 
 ├
equipment:InventoryStatus Hardware component inventory status.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
lstorage:ControllerDef
 
 
 
 ├
lstorage:ControllerModeConfig
 
 
 
 ├
lstorage:ControllerQualifier
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 ├
storage:Drive
 
 
 ├
storage:EmbeddedStorage Class for embedded storage of NVMe HHHL form factor
 
 
 ├
storage:Enclosure
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
storage:EnclosureDiskSlotEp Indicates the disk slot in an enclosure. When the slot is populated, peerDn references the disk present. This is the same as the LocalDiskSlotEp mo. This mo was created because of a conflict between LocalDiskSlotEp and LocalDisk. Both have the same rn and therefore cannot be contained under the same container.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
storage:ControllerRef Represents ownership for server,controller combination
 
 
 
 ├
storage:EnclosureFsm
 
 
 
 
 ├
storage:EnclosureFsmStage
 
 
 
 ├
storage:EnclosureFsmTask
 
 
 
 ├
storage:HddMotherBoardTempStats
 
 
 
 
 ├
storage:HddMotherBoardTempStatsHist
 
 
 
 ├
storage:LocalDiskLocalDisk identifies the physical storage device, a group of LocalDisks can be partitioned into VirtualDrive (or LunDisk in the old code). All of them are child MOs under Storage::Controller.
 
 
 
 
 ├
equipment:LocatorLed
 
 
 
 
 
 ├
equipment:LocatorLedFsm
 
 
 
 
 
 
 ├
equipment:LocatorLedFsmStage
 
 
 
 
 
 ├
equipment:LocatorLedFsmTask
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
mgmt:Controller Controller
 
 
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fabric:Locale
 
 
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 
 
 ├
mgmt:Connection
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 
 
 ├
mgmt:Interface
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 
 
 ├
storage:ControllerEp
 
 
 
 
 ├
storage:DiskEnvStats
 
 
 
 
 
 ├
storage:DiskEnvStatsHist
 
 
 
 
 ├
storage:LocalDiskFsm
 
 
 
 
 
 ├
storage:LocalDiskFsmStage
 
 
 
 
 ├
storage:LocalDiskFsmTask
 
 
 
 
 ├
storage:LocalDiskPartition identifies a partition as identified by fdisk
 
 
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 
 
 ├
storage:SasPort Represents SAS port on disk
 
 
 
 
 ├
storage:SsdHealthStats
 
 
 
 
 
 ├
storage:SsdHealthStatsHist
 
 
 ├
storage:LocalDiskLocalDisk identifies the physical storage device, a group of LocalDisks can be partitioned into VirtualDrive (or LunDisk in the old code). All of them are child MOs under Storage::Controller.
 
 
 
 ├
equipment:LocatorLed
 
 
 
 
 ├
equipment:LocatorLedFsm
 
 
 
 
 
 ├
equipment:LocatorLedFsmStage
 
 
 
 
 ├
equipment:LocatorLedFsmTask
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
mgmt:Controller Controller
 
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fabric:Locale
 
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 
 ├
mgmt:Connection
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 
 ├
mgmt:Interface
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 
 ├
storage:ControllerEp
 
 
 
 ├
storage:DiskEnvStats
 
 
 
 
 ├
storage:DiskEnvStatsHist
 
 
 
 ├
storage:LocalDiskFsm
 
 
 
 
 ├
storage:LocalDiskFsmStage
 
 
 
 ├
storage:LocalDiskFsmTask
 
 
 
 ├
storage:LocalDiskPartition identifies a partition as identified by fdisk
 
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 
 ├
storage:SasPort Represents SAS port on disk
 
 
 
 ├
storage:SsdHealthStats
 
 
 
 
 ├
storage:SsdHealthStatsHist
 
 
 ├
storage:LocalDiskConfigDef LocalDiskConfig
 
 
 
 ├
lstorage:Security
 
 
 
 
 ├
lstorage:DriveSecurity
 
 
 
 
 
 ├
lstorage:Local
 
 
 
 
 
 ├
lstorage:Remote
 
 
 
 
 
 
 ├
lstorage:Login This is used to store the login information for KMIP server
 
 
 
 ├
storage:LocalDiskPartition identifies a partition as identified by fdisk
 
 
 ├
storage:LocalDiskEp Represents SAS/SATA connectivity to a physical disk. This object is created to indicate a SCSI controller has physical connectivity to \ the specified {@link storage:LocalDisk}. In addition, when the disk is accessed \ through a SAS link, the SAS expander must be configured to expose the physical disk to the SCSI controller.
 
 
 ├
storage:LocalLun
 
 
 ├
storage:MezzFlashLife SAS Expander MO :end % Flash Life
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
storage:NvmeStats
 
 
 
 ├
storage:NvmeStatsHist
 
 
 ├
storage:NvmeStorageAdding a new MO for all NVMe related properties. Right now it has only one field but this will increase going forward. Idea is to segregate NVMe specific properties from generic storage controller MO
 
 
 ├
storage:OnboardDevice OnBoard Device This MO can represent any component that is part of a storage controller etc
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 ├
storage:RaidBattery RAID battery to capture battery faults
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 
 ├
storage:TransportableFlashModule TFM to capture flash module powered by supercap which is a type of RaidBattery
 
 
 ├
storage:VirtualDrive Storage physical drives are grouped as Drive Group, a drive group then can be partitioned into virtual drives. Each virtual drive appears as a physical device to the O/S.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
storage:ControllerEp
 
 
 
 ├
storage:LunDisk A logical unit number, or LUN, is a number used to identify a logical storage unit. A LUN may be used with any device which supports read/write operations, but is most often used to refer to a logical disk as created on a SAN. LunDisk refers to the logical disk, it's deprecated and replaced with VirtualDrive
 
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 
 ├
storage:ScsiLunRef ScsiLunRef is to keep track of the location of LUN item defined storage profile (or profile def). This meta-data is guaranteed to be persisted in the storage target.
 
 
 
 ├
storage:VDMemberEp Reference to LocalDisk to build up a VirtualDrive
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
storage:VirtualDriveEp
 
 ├
storage:Enclosure
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
storage:EnclosureDiskSlotEp Indicates the disk slot in an enclosure. When the slot is populated, peerDn references the disk present. This is the same as the LocalDiskSlotEp mo. This mo was created because of a conflict between LocalDiskSlotEp and LocalDisk. Both have the same rn and therefore cannot be contained under the same container.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
storage:ControllerRef Represents ownership for server,controller combination
 
 
 ├
storage:EnclosureFsm
 
 
 
 ├
storage:EnclosureFsmStage
 
 
 ├
storage:EnclosureFsmTask
 
 
 ├
storage:HddMotherBoardTempStats
 
 
 
 ├
storage:HddMotherBoardTempStatsHist
 
 
 ├
storage:LocalDiskLocalDisk identifies the physical storage device, a group of LocalDisks can be partitioned into VirtualDrive (or LunDisk in the old code). All of them are child MOs under Storage::Controller.
 
 
 
 ├
equipment:LocatorLed
 
 
 
 
 ├
equipment:LocatorLedFsm
 
 
 
 
 
 ├
equipment:LocatorLedFsmStage
 
 
 
 
 ├
equipment:LocatorLedFsmTask
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
mgmt:Controller Controller
 
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fabric:Locale
 
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 
 ├
mgmt:Connection
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 
 ├
mgmt:Interface
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 
 ├
storage:ControllerEp
 
 
 
 ├
storage:DiskEnvStats
 
 
 
 
 ├
storage:DiskEnvStatsHist
 
 
 
 ├
storage:LocalDiskFsm
 
 
 
 
 ├
storage:LocalDiskFsmStage
 
 
 
 ├
storage:LocalDiskFsmTask
 
 
 
 ├
storage:LocalDiskPartition identifies a partition as identified by fdisk
 
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 
 ├
storage:SasPort Represents SAS port on disk
 
 
 
 ├
storage:SsdHealthStats
 
 
 
 
 ├
storage:SsdHealthStatsHist
 
 ├
storage:SasExpander Represents a SAS Expander that exposes the physical disks to the SCSI controller
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 ├
storage:OnboardDevice OnBoard Device This MO can represent any component that is part of a storage controller etc
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
storage:SasUpLink Represents SAS uplink connected to SAS Expander
 
 ├
storage:VirtualDriveContainer
 
 
 ├
storage:VirtualDrive Storage physical drives are grouped as Drive Group, a drive group then can be partitioned into virtual drives. Each virtual drive appears as a physical device to the O/S.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
storage:ControllerEp
 
 
 
 ├
storage:LunDisk A logical unit number, or LUN, is a number used to identify a logical storage unit. A LUN may be used with any device which supports read/write operations, but is most often used to refer to a logical disk as created on a SAN. LunDisk refers to the logical disk, it's deprecated and replaced with VirtualDrive
 
 
 
 ├
storage:Operation Operation mo is defined to report on long running operations
 
 
 
 ├
storage:ScsiLunRef ScsiLunRef is to keep track of the location of LUN item defined storage profile (or profile def). This meta-data is guaranteed to be persisted in the storage target.
 
 
 
 ├
storage:VDMemberEp Reference to LocalDisk to build up a VirtualDrive
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
vnic:RackServerDiscoveryProfile RackServerDiscoveryProfile is used for profiles, user can not mutate these
 
 
 ├
sw:Vlan
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
equipment:Fex
 
 ├
equipment:Fan Represents a fan in a Fan module.
 
 
 ├
equipment:FanStats
 
 
 
 ├
equipment:FanStatsHist
 
 
 ├
equipment:NetworkElementFanStats
 
 
 
 ├
equipment:NetworkElementFanStatsHist
 
 
 ├
equipment:RackUnitFanStats
 
 
 
 ├
equipment:RackUnitFanStatsHist
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
equipment:FexEnvStats
 
 
 ├
equipment:FexEnvStatsHist
 
 ├
equipment:FexFsm
 
 
 ├
equipment:FexFsmStage
 
 ├
equipment:FexFsmTask
 
 ├
equipment:FexPowerSummary
 
 
 ├
equipment:FexPowerSummaryHist
 
 ├
equipment:FexPsuInputStats
 
 
 ├
equipment:FexPsuInputStatsHist
 
 ├
equipment:FexSystemStats
 
 
 ├
equipment:FexSystemStatsHist
 
 ├
equipment:IOCard Represents an inventoried IO Card on a device, such as an IO module on a UCS chassis or FEX. This object is created implicitly when an IO Card is detected during hardware discovery.
 
 
 ├
equipment:IOCardBaseFsm
 
 
 
 ├
equipment:IOCardBaseFsmStage
 
 
 ├
equipment:IOCardBaseFsmTask
 
 
 ├
equipment:IOCardFsm
 
 
 
 ├
equipment:IOCardFsmStage
 
 
 ├
equipment:IOCardFsmTask
 
 
 ├
equipment:IOCardStats
 
 
 
 ├
equipment:IOCardStatsHist
 
 
 ├
equipment:Led
 
 
 ├
equipment:POST
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
fault:SuppressTask
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
trig:LocalSched A locally defined user-defined schedule. The schedule is contained locally by the Managed Object that needs the schedule, as opposed to being referred by name.
 
 
 
 
 ├
trig:SchedWindow Scheduled Window.
 
 
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:Controller Controller
 
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 
 ├
event:Inst
 
 
 
 ├
fabric:Locale
 
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:Path
 
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 
 ├
mgmt:Connection
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ControllerFsm
 
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 
 ├
mgmt:ControllerFsmTask
 
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 
 ├
dhcp:Acquired
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 
 ├
mgmt:IfFsmTask
 
 
 
 ├
mgmt:Interface
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:KvmCertificate
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 
 ├
port:Group A collection of physical ports on a device. A port group is created implicitly during device discovery of IO devices such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis. All the ports in a portGroup have the same type (i.e. FC, Ethernet).
 
 
 
 ├
ether:ServerIntFIoPc
 
 
 
 
 ├
ether:ServerIntFIoPcEp
 
 
 
 ├
ether:SwitchIntFIoPc
 
 
 
 
 ├
ether:NiErrStats
 
 
 
 
 
 ├
ether:NiErrStatsHist
 
 
 
 
 ├
ether:SwitchIntFIoPcEp
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
port:IntFIo Abstraction of a physical port on an IO Card.
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 ├
network:IfStats
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 ├
port:PIoFsmTask
 
 
 
 ├
port:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 
 ├
network:IfStats
 
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 
 ├
port:PIoFsmTask
 
 ├
equipment:Led
 
 ├
equipment:POST
 
 ├
equipment:Psu Represents an inventoried Power Supply Unit. This object is created implicitly when a Power Supply Unit is detected during equipment discovery.
 
 
 ├
equipment:FexPsuInputStats
 
 
 
 ├
equipment:FexPsuInputStatsHist
 
 
 ├
equipment:Led
 
 
 ├
equipment:PsuFsm
 
 
 
 ├
equipment:PsuFsmStage
 
 
 ├
equipment:PsuFsmTask
 
 
 ├
equipment:PsuInputStats Mike asked me to create a new object for the PSU input stats.
 
 
 
 ├
equipment:PsuInputStatsHist
 
 
 ├
equipment:PsuOutputStats
 
 
 
 ├
equipment:PsuOutputStatsHist
 
 
 ├
equipment:PsuStats
 
 
 
 ├
equipment:PsuStatsHist
 
 
 ├
equipment:RackUnitPsuStats
 
 
 
 ├
equipment:RackUnitPsuStatsHist
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 ├
event:Inst
 
 ├
fabric:Locale
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Cmclan
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 ├
sw:Ulan
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 ├
fabric:Path
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:PathConn
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fabric:PathEp
 
 
 
 
 ├
port:TrustMode
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
fault:SuppressTask
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
trig:LocalSched A locally defined user-defined schedule. The schedule is contained locally by the Managed Object that needs the schedule, as opposed to being referred by name.
 
 
 
 ├
trig:SchedWindow Scheduled Window.
 
 ├
mgmt:Controller Controller
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 ├
event:Inst
 
 
 ├
fabric:Locale
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:Path
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 ├
mgmt:Connection
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ControllerFsm
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 ├
mgmt:ControllerFsmTask
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 ├
dhcp:Acquired
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 ├
mgmt:IfFsmTask
 
 
 ├
mgmt:Interface
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:KvmCertificate
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
power:Budget Define chassis budget, extend it to include minimum consumption level The FSM properties to deploy chassis budget will also be contained here
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
power:ProfiledPower Power consumption limit of servers from profiling or catalog
 ├
extmgmt:IfMonPolicy
 
 ├
extmgmt:ArpTargets
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
extmgmt:GatewayPing
 
 ├
extmgmt:MiiStatus
 
 ├
extmgmt:NdiscTargets
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
extvmm:Ep SINGLTON THAT CONTAINS ALL THE EXTERNAL VMs
 
 ├
event:Inst
 
 ├
extvmm:EpFsm
 
 
 ├
extvmm:EpFsmStage
 
 ├
extvmm:EpFsmTask
 
 ├
extvmm:KeyStore
 
 
 ├
event:Inst
 
 
 ├
extvmm:KeyRing
 
 
 ├
extvmm:KeyStoreFsm
 
 
 
 ├
extvmm:KeyStoreFsmStage
 
 
 ├
extvmm:KeyStoreFsmTask
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
extvmm:MasterExtKey
 
 
 ├
event:Inst
 
 
 ├
extvmm:MasterExtKeyFsm
 
 
 
 ├
extvmm:MasterExtKeyFsmStage
 
 
 ├
extvmm:MasterExtKeyFsmTask
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
extvmm:Provider REPRESENTS A SINGLE EXTERNAL VM-MANAGEMENT ENTITY
 
 
 ├
event:Inst
 
 
 ├
extvmm:KeyInst
 
 
 ├
extvmm:ProviderFsm
 
 
 
 ├
extvmm:ProviderFsmStage
 
 
 ├
extvmm:ProviderFsmTask
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vm:DirCont
 
 
 ├
vm:Switch
 
 
 
 ├
extvmm:UpLinkPP UplinkPP objects contains references to FNDs. This object is used to link the DVS to the different network sites.
 
 
 
 
 ├
extvmm:FNDReference FNDReference objects are used by uplink port-profiles to determine which fabric network definitions or network sites are avaliable to the DVS. This object maintains a reference to an FND object
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vm:VnicProfInst
 
 
 
 
 ├
vnic:OProfileAlias Other aliases, for non-vmware
 
 
 
 
 ├
vnic:ProfileAlias
 
 ├
extvmm:SwitchDelTask This MO is used to track the deletion task of a given extvmm:Provider MO. When a user deletes a vm:Switch (or any of its parent MOs), the system implicitly creates a extvmm:SwitchDelTask instance. After deletion of the vm:Switch, the user may realize the IP address of vCenter has changed. The user can use the properties of this MO to complete the deletion of the vm:Switch.
 
 
 ├
event:Inst
 
 
 ├
extvmm:SwitchDelTaskFsm
 
 
 
 ├
extvmm:SwitchDelTaskFsmStage
 
 
 ├
extvmm:SwitchDelTaskFsmTask
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
extvmm:SwitchSet a collection of generic vSwitch MOs
 
 
 ├
vm:Switch
 
 
 
 ├
extvmm:UpLinkPP UplinkPP objects contains references to FNDs. This object is used to link the DVS to the different network sites.
 
 
 
 
 ├
extvmm:FNDReference FNDReference objects are used by uplink port-profiles to determine which fabric network definitions or network sites are avaliable to the DVS. This object maintains a reference to an FND object
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vm:VnicProfInst
 
 
 
 
 ├
vnic:OProfileAlias Other aliases, for non-vmware
 
 
 
 
 ├
vnic:ProfileAlias
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
feature:ContextEp This object contains ProviderInstance which are instantiated in the system.
 
 ├
feature:DefinitionInstance This object represents a feature definition instance which is created under ProviderInstance parent This is used to determine if a particular feature is supported or not in the system when queried.
 
 ├
feature:FruCapProviderInstance This object represents a FruCapProvider instance which is created under ProviderInstance parent This is used to determine if a particular harware element is supported or not in the system when queried.
 
 ├
feature:ProviderInstance Represents a ProviderInstance created in the system.
 ├
firmware:Catalogue Represents a library of firmware images like downloaded images, installables etc
 
 ├
firmware:CompSource
 
 
 ├
firmware:CompTarget
 
 ├
firmware:Distributable Represents a distributable (downloadable) bundle. UCS includes the infrastructure bundle, the "blade" bundle and the "rack-server" bundle. A bundle contains {@link firmware:DistImage} images.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:DistImage Represents a component image of distributable package. Has one-to-one correspondence with installable object. Useful to display contents of a bundle image and their current status (Whether installable is deleted).
 
 
 ├
firmware:DistributableFsm
 
 
 
 ├
firmware:DistributableFsmStage
 
 
 ├
firmware:DistributableFsmTask
 
 ├
firmware:Downloader Represents a download operation. Could be active or executed in the past. Used to display the status of various download operations in progress.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:DownloaderFsm
 
 
 
 ├
firmware:DownloaderFsmStage
 
 
 ├
firmware:DownloaderFsmTask
 
 ├
firmware:Image Represents a physical image file in bootflash. Created implicitely as part of download operation.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:ImageFsm
 
 
 
 ├
firmware:ImageFsmStage
 
 
 ├
firmware:ImageFsmTask
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Module
 
 ├
firmware:UcscInfo
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
firmware:System Represents system firmware. i.e, the firmware package for the whole system
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
firmware:Ack Ack object used by Install-All to get user's acknowledgement before rebooting primary FI
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
trig:LocalSched A locally defined user-defined schedule. The schedule is contained locally by the Managed Object that needs the schedule, as opposed to being referred by name.
 
 
 
 ├
trig:SchedWindow Scheduled Window.
 
 ├
firmware:Host
 
 
 ├
firmware:Blade
 
 
 ├
firmware:Rack
 
 ├
firmware:Infra
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
trig:LocalSched A locally defined user-defined schedule. The schedule is contained locally by the Managed Object that needs the schedule, as opposed to being referred by name.
 
 
 
 ├
trig:SchedWindow Scheduled Window.
 
 ├
firmware:SystemCompCheckResult
 
 ├
firmware:SystemFsm
 
 
 ├
firmware:SystemFsmStage
 
 ├
firmware:SystemFsmTask
 ├
firmware:UpgradeInfo Used to persist validation logs during ucsm upgrade in validation mode.
 
 ├
firmware:UpgradeDetail
 ├
fsm:Status Task status of an UCS object
 ├
initiator:RequestorEp Beginning of objects related to storage devices this represents the compute node
 
 ├
initiator:GroupEp
 
 
 ├
initiator:InitiatorEp this represents the hostep that a Lun is visible to
 
 
 
 ├
storage:EpUser
 
 
 
 
 ├
aaa:CimcSession
 
 
 ├
initiator:StoreEp
 
 
 ├
storage:NodeEp
 
 
 
 ├
storage:IScsiTargetIf
 
 
 
 
 ├
initiator:LunEp
 
 
 
 
 ├
storage:AuthKey
 
 
 
 
 ├
storage:EtherIf
 
 
 
 
 
 ├
ip:ServiceIf
 ├
initiator:RequestorGrpEp
 
 ├
initiator:MemberEp
 
 ├
initiator:UnitEp this is the object that is created when UCSM requests a LUN for a vnic
 ├
license:Ep The system-level endpoint for licensing contains Mos representing the system-wide properties of licensable features. It is a singleton.
 
 ├
license:Downloader Represents a download operation. Could be active or executed in the past. Used to display the status of various download operations in progress.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
license:DownloaderFsm
 
 
 
 ├
license:DownloaderFsmStage
 
 
 ├
license:DownloaderFsmTask
 
 
 ├
license:Prop The user may "tag" a license with a set of "name=value" pairs. They are stored here (e.g., "A=X;B=Y;C=Z").
 
 ├
license:Feature A system-wide representation of a licensable feature exists to specify system-wide properties of that feature. It is identified by the {name, vendor, version} triplet.
 
 
 ├
license:Instance Instance MOs correspond to actual FLEXlm (or other) licenses supplied by the user in a license file. Licenses are uniquely identified by the {fileId, lineId} pair.
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
license:InstanceFsm
 
 
 
 
 ├
license:InstanceFsmStage
 
 
 
 ├
license:InstanceFsmTask
 
 
 
 ├
license:Prop The user may "tag" a license with a set of "name=value" pairs. They are stored here (e.g., "A=X;B=Y;C=Z").
 
 
 
 ├
license:SourceFile
 
 
 
 ├
license:Target Represents Port using a specific feature.
 
 ├
license:File License file Mos correspond to actual FLEXlm (or other) license files supplied by the user. While the file body is not stored directly as a property of the Mo, all of the essential attributes are represented either as properties of the license file Mo or the subordinate license Mos. The actual file contents are stored in the file system under /o...
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
license:Contents This Mo represents the contents from the downloaded file. If the file is found to be valid, an instance of File Mo would be created and the file contents would be stored under Content MOs. So, a File MO can have multiple Content MOs based on the no of different features it has.
 
 
 
 ├
license:FeatureLine This MO represents Line Id, type of the feature, PAK, SIGN, Feature line Quantity (no of licenses contributed by this line) and expiration date values for each feature line, from this license file
 
 
 ├
license:FileFsm
 
 
 
 ├
license:FileFsmStage
 
 
 ├
license:FileFsmTask
 
 
 ├
license:Source
 
 ├
license:ServerHostId A system-wide representation of a licensable feature exists to specify system-wide properties of that feature. It is identified by the {name, vendor, version} triplet.
 ├
mgmt:AccessPolicy
 
 ├
mgmt:AccessPolicyItem
 
 
 ├
mgmt:AccessPort
 ├
mgmt:Backup
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:BackupFsm
 
 
 ├
mgmt:BackupFsmStage
 
 ├
mgmt:BackupFsmTask
 ├
mgmt:BackupPolicyConfig
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
trig:LocalSched A locally defined user-defined schedule. The schedule is contained locally by the Managed Object that needs the schedule, as opposed to being referred by name.
 
 
 ├
trig:SchedWindow Scheduled Window.
 ├
mgmt:Controller Controller
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 ├
event:Inst
 
 ├
fabric:Locale
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Cmclan
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 ├
sw:Ulan
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 ├
fabric:Path
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:PathConn
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 ├
fabric:PathEp
 
 
 
 
 ├
port:TrustMode
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 ├
firmware:BootUnit
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:UcscInfo
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 ├
firmware:UcscInfo
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 ├
mgmt:Connection
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:ControllerFsm
 
 
 ├
mgmt:ControllerFsmStage
 
 ├
mgmt:ControllerFsmTask
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 ├
dhcp:Acquired
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 ├
mgmt:IfFsm
 
 
 
 ├
mgmt:IfFsmStage
 
 
 ├
mgmt:IfFsmTask
 
 ├
mgmt:Interface
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:Vnet
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 ├
mgmt:KvmCertificate
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 ├
mgmt:Vnet
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 ├
mgmt:UsbNicMgmtIf
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 ├
vnic:IpV4ProfDerivedAddr
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 ├
mgmt:Entity
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:PmonEntry
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
mgmt:Importer
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:ImporterFsm
 
 
 ├
mgmt:ImporterFsmStage
 
 ├
mgmt:ImporterFsmTask
 ├
mgmt:IntAuthPolicy
 ├
network:Element Represents a physical network element, such as a Fabric Interconnect.
 
 ├
equipment:Fan Represents a fan in a Fan module.
 
 
 ├
equipment:FanStats
 
 
 
 ├
equipment:FanStatsHist
 
 
 ├
equipment:NetworkElementFanStats
 
 
 
 ├
equipment:NetworkElementFanStatsHist
 
 
 ├
equipment:RackUnitFanStats
 
 
 
 ├
equipment:RackUnitFanStatsHist
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
equipment:FanModule Represents an inventoried Fan module. This object is created implicitly when a Fan module is detected during equipment discovery.
 
 
 ├
equipment:Fan Represents a fan in a Fan module.
 
 
 
 ├
equipment:FanStats
 
 
 
 
 ├
equipment:FanStatsHist
 
 
 
 ├
equipment:NetworkElementFanStats
 
 
 
 
 ├
equipment:NetworkElementFanStatsHist
 
 
 
 ├
equipment:RackUnitFanStats
 
 
 
 
 ├
equipment:RackUnitFanStatsHist
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
equipment:FanModuleStats
 
 
 
 ├
equipment:FanModuleStatsHist
 
 
 ├
equipment:Led
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
equipment:LocatorLed
 
 
 ├
equipment:LocatorLedFsm
 
 
 
 ├
equipment:LocatorLedFsmStage
 
 
 ├
equipment:LocatorLedFsmTask
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
equipment:Psu Represents an inventoried Power Supply Unit. This object is created implicitly when a Power Supply Unit is detected during equipment discovery.
 
 
 ├
equipment:FexPsuInputStats
 
 
 
 ├
equipment:FexPsuInputStatsHist
 
 
 ├
equipment:Led
 
 
 ├
equipment:PsuFsm
 
 
 
 ├
equipment:PsuFsmStage
 
 
 ├
equipment:PsuFsmTask
 
 
 ├
equipment:PsuInputStats Mike asked me to create a new object for the PSU input stats.
 
 
 
 ├
equipment:PsuInputStatsHist
 
 
 ├
equipment:PsuOutputStats
 
 
 
 ├
equipment:PsuOutputStatsHist
 
 
 ├
equipment:PsuStats
 
 
 
 ├
equipment:PsuStatsHist
 
 
 ├
equipment:RackUnitPsuStats
 
 
 
 ├
equipment:RackUnitPsuStatsHist
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 ├
equipment:SwitchCard Represents a physical switch card, such as a fixed module on a Fabric Interconnect or an extension module. This object is automatically created through hardware discovery.
 
 
 ├
equipment:BeaconLed
 
 
 
 ├
equipment:BeaconLedFsm
 
 
 
 
 ├
equipment:BeaconLedFsmStage
 
 
 
 ├
equipment:BeaconLedFsmTask
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
port:Group A collection of physical ports on a device. A port group is created implicitly during device discovery of IO devices such as IO cards on a Fabric Interconnect, or IO modules on a UCS chassis. All the ports in a portGroup have the same type (i.e. FC, Ethernet).
 
 
 
 ├
ether:ServerIntFIoPc
 
 
 
 
 ├
ether:ServerIntFIoPcEp
 
 
 
 ├
ether:SwitchIntFIoPc
 
 
 
 
 ├
ether:NiErrStats
 
 
 
 
 
 ├
ether:NiErrStatsHist
 
 
 
 
 ├
ether:SwitchIntFIoPcEp
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
port:IntFIo Abstraction of a physical port on an IO Card.
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 ├
event:Inst
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 ├
network:IfStats
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 ├
port:PIoFsmTask
 
 
 
 ├
port:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 
 ├
port:PIo An abstraction of a Physical Port on a Fabric Interconnect switch device.
 
 
 
 
 
 ├
equipment:Xcvr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
lldp:Acquired
 
 
 
 
 
 ├
network:IfStats
 
 
 
 
 
 ├
port:DomainEp
 
 
 
 
 
 ├
port:PIoFsm
 
 
 
 
 
 
 ├
port:PIoFsmStage
 
 
 
 
 
 ├
port:PIoFsmTask
 
 ├
extmgmt:If
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
firmware:Status A registered client for monitoring firmware update progress
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:Controller Controller
 
 
 ├
cimcvmedia:ActualMountList This is the container for ActualMountEntries and maintained under computePhysicalMo
 
 
 
 ├
cimcvmedia:ActualMountEntry This MO represents the deployed configuration for each of the vmedia mappings(ex:CD or HDD)
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
cimcvmedia:ExtMgmtRuleEntry This Mo represents the deployed configuration for the ExtMgmtRules(ex:NAT/Firewall)
 
 
 ├
event:Inst
 
 
 ├
fabric:Locale
 
 
 
 ├
adaptor:ExtEthIfPc Network facing Ethernet port channel interface on a server adaptor. For example, on a network adaptor installed on a UCS blade, this MO represents the Ethernet port channel interface connected to the IO Module on the UCS chassis. In this case, the peer of this MO is a Server facing Ethernet interface on the IOM.
 
 
 
 
 ├
adaptor:ExtEthIfPcEp
 
 
 
 
 ├
dcx:VIf A Virtual Interface.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
fabric:Path
 
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
fabric:PathConn
 
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
fabric:PathEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
firmware:BootDefinition Container for BootUnit objects. This is needed since some components (like switch) have more then one BootUnit objects.
 
 
 
 ├
firmware:BootUnit
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 
 ├
firmware:UcscInfo
 
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
firmware:Running Representation of primary firmware image (Currently running)
 
 
 
 ├
firmware:ServicePack Representation of firmware image version that is loaded at reboot. Applicable to all the components that supports one or more backup image(s).
 
 
 ├
firmware:Updatable Representation of backup firmware image for the chassis components that supports backup image (CMC/BMC/BIOS/Adaptor etc)
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
firmware:Installable Represents a logical image that can be installed on an end-point. Ech physical File can have one or more installables. This is to Support Model changes without any software change. Created implicitely as part of download operation.
 
 
 
 
 ├
firmware:UcscInfo
 
 
 ├
mgmt:ASecureBoot MO used to hold the admin and operational state of the secure boot status of the BMC/CMC.
 
 
 ├
mgmt:Connection
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ControllerFsm
 
 
 
 ├
mgmt:ControllerFsmStage
 
 
 ├
mgmt:ControllerFsmTask
 
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 
 ├
mgmt:If Encapsulates the configuration of a CIMC management interface.
 
 
 
 ├
dhcp:Acquired
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfConfig
 
 
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 
 
 ├
mgmt:IfFsm
 
 
 
 
 ├
mgmt:IfFsmStage
 
 
 
 ├
mgmt:IfFsmTask
 
 
 ├
mgmt:Interface
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:KvmCertificate
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:ProfDerivedInterface This MO represents how a logical server profile is configured for CIMC management.
 
 
 
 ├
mgmt:Vnet
 
 
 
 
 ├
vnic:IpV4AddrExplConf
 
 
 
 
 ├
vnic:IpV6AddrExplConf
 
 
 ├
mgmt:UsbNicMgmtIf
 
 
 ├
sysdebug:MEpLog This object represents the status of a remote managed end-point log.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
vnic:IpV4PooledAddr Represents the IPv4 address of an IP interface, where the IP address is obtained from a pool of IP addresses.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
vnic:IpV4History A temporary object used to hold the history of ipv4 address of MOs.
 
 
 ├
vnic:IpV4ProfDerivedAddr
 
 
 ├
vnic:IpV4StaticAddr Represents a statically assigned IPv4 address.
 
 ├
mgmt:DbState
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:HealthStatus This MO represents an aggregation of all the individual health attributes mos
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
mgmt:HealthAttr This MO represents health attributes from BMC/CMC
 
 ├
mgmt:IPv6IfConfig
 
 
 ├
mgmt:IPv6IfAddr
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
mgmt:IPv6IfAddrFsm
 
 
 
 
 ├
mgmt:IPv6IfAddrFsmStage
 
 
 
 ├
mgmt:IPv6IfAddrFsmTask
 
 ├
network:LanNeighbors
 
 
 ├
network:LanNeighborEntry
 
 ├
network:Limit Represents a logical object under the network element which is used to track the various counts that are there in the switch
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
network:LldpNeighbors
 
 
 ├
network:LldpNeighborEntry
 
 ├
network:OperLevel Represents a logical object under the network element which is used to track how many primary vlans are there in the switch and is it within the limits specified by the capability catalogue.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
network:SanNeighbors
 
 
 ├
network:SanNeighborEntry
 
 ├
nfs:MountInst MountInst represents the mount point based on MountDef. mount/umount FSMs are defined on this object.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
nfs:MountInstFsm
 
 
 
 ├
nfs:MountInstFsmStage
 
 
 ├
nfs:MountInstFsmTask
 
 ├
power:Budget Define chassis budget, extend it to include minimum consumption level The FSM properties to deploy chassis budget will also be contained here
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
power:ProfiledPower Power consumption limit of servers from profiling or catalog
 
 ├
storage:Item
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
sw:AccessDomain
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:AccessDomainFsm
 
 
 
 ├
sw:AccessDomainFsmStage
 
 
 ├
sw:AccessDomainFsmTask
 
 
 ├
sw:AccessEp
 
 
 
 ├
port:TrustMode
 
 
 
 ├
sw:Ulan
 
 
 ├
sw:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 ├
sw:AccessEp
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
sw:Ulan
 
 
 
 ├
sw:EthEstcEp
 
 
 
 
 ├
sw:EthTargetEp
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthLanEp Represents a Ethernet LAN Border Physical Port.
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthMonDestEp switch:EthMonDestEp is the MO that is used to send the configuration of an ethernet SPAN destination port to portAG
 
 
 
 ├
sw:EthMonSrcEp
 
 
 
 ├
sw:FcoeEstcEp
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:FcoeSanEp Represents a FCOE SAN Border Physical Port.
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:PhysEtherEp Represents the desired configuration state of an Ethernet port on a Fabric Interconnect.
 
 
 
 ├
sw:PhysFcEp Represents the desired configuration state of a FC port on a Fabric Interconnect.
 
 ├
sw:CardEnvStats
 
 
 ├
sw:CardEnvStatsHist
 
 ├
sw:EnvStats
 
 
 ├
sw:EnvStatsHist
 
 ├
sw:EthLanBorder Represents Switch Ethernet LAN Border Domain which is a collection of Ethernet physical ports and port channels and their configurations.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:EthEstcEp
 
 
 
 ├
sw:EthTargetEp
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:EthEstcPc
 
 
 
 ├
sw:EthTargetEp
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:EthLanBorderFsm
 
 
 
 ├
sw:EthLanBorderFsmStage
 
 
 ├
sw:EthLanBorderFsmTask
 
 
 ├
sw:EthLanEp Represents a Ethernet LAN Border Physical Port.
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:EthLanPc Represents a Ethernet LAN Border Port Channel.
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 ├
sw:AccessEp
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
sw:Ulan
 
 
 
 ├
sw:EthEstcEp
 
 
 
 
 ├
sw:EthTargetEp
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthLanEp Represents a Ethernet LAN Border Physical Port.
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthMonDestEp switch:EthMonDestEp is the MO that is used to send the configuration of an ethernet SPAN destination port to portAG
 
 
 
 ├
sw:EthMonSrcEp
 
 
 
 ├
sw:FcoeEstcEp
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:FcoeSanEp Represents a FCOE SAN Border Physical Port.
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:PhysEtherEp Represents the desired configuration state of an Ethernet port on a Fabric Interconnect.
 
 
 
 ├
sw:PhysFcEp Represents the desired configuration state of a FC port on a Fabric Interconnect.
 
 
 ├
sw:Vlan
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:VlanGroup A Group containing zero or more sw:Vlan instances. This object is used to model VLAN compression groups.
 
 
 
 ├
sw:VIFRef A reference to a VIF
 
 
 
 ├
sw:VlanRef A reference to a sw:Vlan
 
 ├
sw:EthLanFlowMon Netflow related model.
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Cmclan
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 ├
sw:Ulan
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:EthLanFlowMonFsm
 
 
 
 ├
sw:EthLanFlowMonFsmStage
 
 
 ├
sw:EthLanFlowMonFsmTask
 
 
 ├
sw:IpRoute
 
 
 ├
sw:NetflowExporter
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:NetflowMonSession
 
 
 
 ├
sw:NetflowMonitor
 
 
 
 
 ├
sw:NFExporterRef
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 ├
sw:NetflowMonitor
 
 
 
 ├
sw:NFExporterRef
 
 
 ├
sw:NetflowRecordDef
 
 
 ├
sw:VirtL3Intf SVI representation
 
 ├
sw:EthLanMon
 
 
 ├
sw:EthMon
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthEstcPc
 
 
 
 
 ├
sw:EthTargetEp
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthLanPc Represents a Ethernet LAN Border Port Channel.
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthMonDestEp switch:EthMonDestEp is the MO that is used to send the configuration of an ethernet SPAN destination port to portAG
 
 
 
 ├
sw:EthMonFsm
 
 
 
 
 ├
sw:EthMonFsmStage
 
 
 
 ├
sw:EthMonFsmTask
 
 
 
 ├
sw:EthMonSrcEp
 
 
 
 ├
sw:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 
 ├
sw:AccessEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:EthEstcEp
 
 
 
 
 
 ├
sw:EthTargetEp
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:EthLanEp Represents a Ethernet LAN Border Physical Port.
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:EthMonDestEp switch:EthMonDestEp is the MO that is used to send the configuration of an ethernet SPAN destination port to portAG
 
 
 
 
 ├
sw:EthMonSrcEp
 
 
 
 
 ├
sw:FcoeEstcEp
 
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:FcoeSanEp Represents a FCOE SAN Border Physical Port.
 
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:PhysEtherEp Represents the desired configuration state of an Ethernet port on a Fabric Interconnect.
 
 
 
 
 ├
sw:PhysFcEp Represents the desired configuration state of a FC port on a Fabric Interconnect.
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
sw:ExtUtility Represents config on network element, such as a Fabric Interconnect. This object is a child of network:Element and is used to model the port breakout on a particular Fabric Interconnect.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:ExtUtilityFsm
 
 
 
 ├
sw:ExtUtilityFsmStage
 
 
 ├
sw:ExtUtilityFsmTask
 
 
 ├
sw:PortBreakout
 
 ├
sw:FabricZoneNs
 
 ├
sw:FcSanBorder Represents Switch FC LAN Border Domain which is a collection of FC physical ports and their configurations.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:FcEstcEp
 
 
 ├
sw:FcSanBorderFsm
 
 
 
 ├
sw:FcSanBorderFsmStage
 
 
 ├
sw:FcSanBorderFsmTask
 
 
 ├
sw:FcSanEp Represents a FC SAN Border Physical Port.
 
 
 ├
sw:FcSanPc Represents a FC SAN Border Port Channel.
 
 
 ├
sw:FcoeEstcEp
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
dcx:VifEp
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:FcoeSanEp Represents a FCOE SAN Border Physical Port.
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
dcx:VifEp
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:FcoeSanPc Represents a FCoE SAN Border Port Channel.
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
dcx:VifEp
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
sw:Vlan
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 ├
sw:AccessEp
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
sw:Ulan
 
 
 
 ├
sw:EthEstcEp
 
 
 
 
 ├
sw:EthTargetEp
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthLanEp Represents a Ethernet LAN Border Physical Port.
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthMonDestEp switch:EthMonDestEp is the MO that is used to send the configuration of an ethernet SPAN destination port to portAG
 
 
 
 ├
sw:EthMonSrcEp
 
 
 
 ├
sw:FcoeEstcEp
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:FcoeSanEp Represents a FCOE SAN Border Physical Port.
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:PhysEtherEp Represents the desired configuration state of an Ethernet port on a Fabric Interconnect.
 
 
 
 ├
sw:PhysFcEp Represents the desired configuration state of a FC port on a Fabric Interconnect.
 
 
 ├
sw:Vlan
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:Vsan A Vsan
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 ├
sw:FcSanMon
 
 
 ├
sw:FcMon
 
 
 
 ├
dcx:Vc Virtual Circuit on a server adaptor, chassis IOM, or FEX. This MO is created implicitly to represent a circuit between two end-points
 
 
 
 
 ├
fabric:ANetGroupRef
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Cmclan
 
 
 
 
 
 ├
fabric:NetGroupRef
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:NetflowMonitorRef
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthMonDestEp switch:EthMonDestEp is the MO that is used to send the configuration of an ethernet SPAN destination port to portAG
 
 
 
 ├
sw:FcMonDestEp switch:FcMonDestEp is the MO that is used to send the configuration of an FC SPAN destination port to portAG
 
 
 
 ├
sw:FcMonFsm
 
 
 
 
 ├
sw:FcMonFsmStage
 
 
 
 ├
sw:FcMonFsmTask
 
 
 
 ├
sw:FcMonSrcEp
 
 
 
 ├
sw:FcSanPc Represents a FC SAN Border Port Channel.
 
 
 
 ├
sw:FcoeSanPc Represents a FCoE SAN Border Port Channel.
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 
 ├
sw:AccessEp
 
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 
 ├
sw:Ulan
 
 
 
 
 ├
sw:EthEstcEp
 
 
 
 
 
 ├
sw:EthTargetEp
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:EthLanEp Represents a Ethernet LAN Border Physical Port.
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:EthMonDestEp switch:EthMonDestEp is the MO that is used to send the configuration of an ethernet SPAN destination port to portAG
 
 
 
 
 ├
sw:EthMonSrcEp
 
 
 
 
 ├
sw:FcoeEstcEp
 
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:FcoeSanEp Represents a FCOE SAN Border Physical Port.
 
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:PhysEtherEp Represents the desired configuration state of an Ethernet port on a Fabric Interconnect.
 
 
 
 
 ├
sw:PhysFcEp Represents the desired configuration state of a FC port on a Fabric Interconnect.
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 ├
sw:Phys Represents a physical network element, such as a Fabric Interconnect. This object is a child of network:Element and is used to model the desired configuration state of Ethernet and FC ports on a particular Fabric Interconnect.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:PhysEtherEp Represents the desired configuration state of an Ethernet port on a Fabric Interconnect.
 
 
 ├
sw:PhysFcEp Represents the desired configuration state of a FC port on a Fabric Interconnect.
 
 
 ├
sw:PhysFsm
 
 
 
 ├
sw:PhysFsmStage
 
 
 ├
sw:PhysFsmTask
 
 
 ├
sw:SubGroup A SubGroup contains ports which are made availabe by connecting a break-out cable to an aggregated port. Example in UCS-Mini a 40GB Scalability port is connected to a 4x10GB breakout cable to get 4 10GB ports.
 
 
 
 ├
sw:AccessEp
 
 
 
 
 ├
port:TrustMode
 
 
 
 
 ├
sw:Ulan
 
 
 
 ├
sw:EthEstcEp
 
 
 
 
 ├
sw:EthTargetEp
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthLanEp Represents a Ethernet LAN Border Physical Port.
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:EthMonDestEp switch:EthMonDestEp is the MO that is used to send the configuration of an ethernet SPAN destination port to portAG
 
 
 
 ├
sw:EthMonSrcEp
 
 
 
 ├
sw:FcoeEstcEp
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:FcoeSanEp Represents a FCOE SAN Border Physical Port.
 
 
 
 
 ├
dcx:FcoeVifEp Vif for FCOE uplink/storage. From elcap-mr1 onwards dcxFcoeVifEp will be used under Fcoe interfaces instead of dcxVifEp. dcxVifEpMo will be used under UniverseMo to hold free vif ids as earlier.
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
dcx:VifEp
 
 
 
 
 
 ├
sw:Vsan A Vsan
 
 
 
 
 
 
 ├
sw:FcZoneSet
 
 
 
 
 
 
 
 ├
sw:FcServerZoneGroup
 
 
 
 
 
 
 
 
 ├
sw:ZoneInitiatorMember
 
 
 
 
 
 
 
 
 
 ├
sw:FcZone
 
 
 
 
 
 
 
 
 
 
 ├
sw:ZoneTargetMember
 
 
 
 
 
 
 
 ├
sw:FcUserZoneGroupA swFcUserZoneGroup is created for every user defined Zone Profile which has a zone under a given zoneset.
 
 
 
 
 
 
 
 
 ├
sw:FcUserZone
 
 
 
 
 
 
 
 
 
 ├
sw:FcEndpoint Fc Zone Initiator/Target Member
 
 
 
 
 ├
sw:Vlan
 
 
 
 
 
 ├
fabric:NetflowIPv4Addr Represents the source ip-address of the SVI on a given fabric. this is in turn used by the exporter vNICs on sereno. Separate vNICs are used per fabric interconnect for exporting flow records to the external collector using the same user specified VLAN. A different source ip is used for each of these vNIC.
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sw:PhysEtherEp Represents the desired configuration state of an Ethernet port on a Fabric Interconnect.
 
 
 
 ├
sw:PhysFcEp Represents the desired configuration state of a FC port on a Fabric Interconnect.
 
 ├
sw:PortDiscover This object is a child of network:Element and is used to enable an unconfigured port which has a transceiver.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:EtherPort
 
 
 ├
sw:PortDiscoverFsm
 
 
 
 ├
sw:PortDiscoverFsmStage
 
 
 ├
sw:PortDiscoverFsmTask
 
 ├
sw:SystemStats
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:SystemStatsHist
 
 ├
sw:UtilityDomain
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sw:Ulan
 
 
 ├
sw:UtilityDomainFsm
 
 
 
 ├
sw:UtilityDomainFsmStage
 
 
 ├
sw:UtilityDomainFsmTask
 
 ├
sw:VlanPortNs
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
pki:Ep PKI config: keyrings and CA certs
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
mgmt:KmipCertPolicy This policy is used to provide configuration to creates certificates on the BMC for use by KMIP client library.
 
 ├
pki:EpFsm
 
 
 ├
pki:EpFsmStage
 
 ├
pki:EpFsmTask
 
 ├
pki:KeyRing
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
pki:CertReq
 
 ├
pki:TP CA object, also called Trust Points in DCOS
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
policy:ControlEp This Mo contains control information for each admin policy
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
policy:CentraleSync
 
 ├
policy:Control Abstract class to specify control information for a policy
 
 
 ├
policy:Controlledmo name="Qos" super="Control" concrete="yes" access="admin,ext-lan-qos,ext-san-qos,ls-network,ls-network-policy,ls-qos-policy" backup="yes" generate="behavior" label="QOS Class Policy Configuration Settings" >
 
 ├
policy:ControlEpFsm
 
 
 ├
policy:ControlEpFsmStage
 
 ├
policy:ControlEpFsmTask
 
 ├
policy:DestEp Define the metadata that defines behavior on how to apply the object from UCS Central to UCSM. Now, it is assumed that the object in Central is always a policy definition. However, the object in UCSM is NOT necessary an policy object policy-mgr needs to transform the central policy object to UCSM non-policy object if needed. When UCSM tries to apply the ob...
 
 
 ├
policy:DestClass
 
 
 
 ├
policy:ChildClass
 
 ├
policy:IdResolvePolicy
 
 ├
policy:SourceApp
 
 
 ├
policy:Context same with policyPolicyScopeContext
 
 
 
 ├
policy:Scope PolicyScope class is to keep track of policy class id and policy name in resolve-policy request, where the combination of context, policy class id and policy name is unique. policy:Digest: name: PolicyScope->policyName type: policyScope->policyType context: ...
 
 
 
 
 ├
policy:PolicyDestClass PolicyDestClass specifies the behavior of policy replication destionation mo behavior (deleted or keep it) when there is no requestor anymore. If there is no PolicyDestClass, and if the policy is org policy, the policy is going to be deleted in UCSM if the policy is domain group policy, and the replicated policy in UCSM is not deleted
 
 
 
 
 
 ├
policy:DestClass
 
 
 
 
 
 
 ├
policy:ChildClass
 
 
 
 
 ├
policy:Requestor PolicyRequestor class to keep track of policyName, onBehalfOfType, and onBehalfOfIdent for a resolve-policy request, where the policyName is unique.
 
 
 
 
 
 ├
event:Inst
 
 
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 
 
 ├
policy:RequestorFsm
 
 
 
 
 
 
 ├
policy:RequestorFsmStage
 
 
 
 
 
 ├
policy:RequestorFsmTask
 ├
power:Ep top level container
 
 ├
power:Group Group represents the power group.
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
power:GroupMember Abstract member of a group
 
 ├
power:PrioWght map priority to weights
 ├
swat:Injection
 
 ├
swat:Action
 
 
 ├
swat:Condition
 
 
 ├
swat:Target
 
 
 ├
swat:Trigger
 
 
 
 ├
swat:Condition
 ├
synthetic:Directory
 
 ├
synthetic:File
 ├
synthetic:FsObj
 
 ├
event:Inst
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 ├
synthetic:FsObjFsm
 
 
 ├
synthetic:FsObjFsmStage
 
 ├
synthetic:FsObjFsmTask
 ├
sysdebug:CoreFileRepository
 
 ├
sysdebug:Core A core dump file.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sysdebug:CoreFsm
 
 
 
 ├
sysdebug:CoreFsmStage
 
 
 ├
sysdebug:CoreFsmTask
 
 
 ├
sysdebug:ManualCoreFileExportTarget
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sysdebug:ManualCoreFileExportTargetFsm
 
 
 
 
 ├
sysdebug:ManualCoreFileExportTargetFsmStage
 
 
 
 ├
sysdebug:ManualCoreFileExportTargetFsmTask
 
 
 ├
sysfile:Mutation
 
 
 
 ├
event:Inst
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 
 ├
sysfile:MutationFsm
 
 
 
 
 ├
sysfile:MutationFsmStage
 
 
 
 ├
sysfile:MutationFsmTask
 
 ├
sysfile:Mutation
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sysfile:MutationFsm
 
 
 
 ├
sysfile:MutationFsmStage
 
 
 ├
sysfile:MutationFsmTask
 ├
sysdebug:DiagnosticLogRepository Repository for diag-log files
 
 ├
sysdebug:DiagnosticLog A Diag-Log file.
 ├
sysdebug:Ep Container for system debug information.
 
 ├
sysdebug:AutoCoreFileExportTarget
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sysdebug:AutoCoreFileExportTargetFsm
 
 
 
 ├
sysdebug:AutoCoreFileExportTargetFsmStage
 
 
 ├
sysdebug:AutoCoreFileExportTargetFsmTask
 
 ├
sysdebug:LogControlEp Log Control endpoint. Contains specific Log Control Domain Endpoints.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sysdebug:LogControlDomain Log Control Domain. An enumeration describes the possible domains.
 
 
 
 ├
sysdebug:LogControlDestinationFile Log Control file destination identifies the log rotation parameters.
 
 
 
 ├
sysdebug:LogControlDestinationSyslog Log Control syslog destination.
 
 
 
 ├
sysdebug:LogControlModule Log Control module.
 
 
 ├
sysdebug:LogControlEpFsm
 
 
 
 ├
sysdebug:LogControlEpFsmStage
 
 
 ├
sysdebug:LogControlEpFsmTask
 
 ├
sysdebug:LogExportPolicy
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sysdebug:LogExportPolicyFsm
 
 
 
 ├
sysdebug:LogExportPolicyFsmStage
 
 
 ├
sysdebug:LogExportPolicyFsmTask
 
 
 ├
sysdebug:LogExportStatus
 
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 ├
sysdebug:TechSupFileRepository Repository for tech-support files
 
 ├
sysdebug:TechSupport A tech-support file.
 
 
 ├
event:Inst
 
 
 ├
fault:Inst An abnormal condition or defect at the component, equipment, or sub-system level which may lead to a failure, as defined in ISO/CD 10303-226.
 
 
 ├
sysdebug:TechSupportCmdOpt Mo holding the command options for a tech support file creation.
 
 
 ├
sysdebug:TechSupportFsm
 
 
 
 ├
sysdebug:TechSupportFsmStage
 
 
 ├
sysdebug:TechSupportFsmTask
 ├
top:InfoPolicy Represents a policy for showing the info from the network element, such as a Fabric Interconnect.
 ├
trig:BaseSched Generic Scheduler. A user-defined schedule that can be used to trigger configuration at a specified date and time in the future. The schedule is defined in the system and can be referred by name from policies that require a schedule. For example, maintenance policies and firmware auto-install policies can refer to user-defined schedules. The schedule can have a list...
 
 ├
trig:SchedWindow Scheduled Window.
 ├
trig:Meta A system-generated Meta Scheduler. This object is automatically created by the system for every trig:BaseSched instance, and is added under top:System. The object is used to track the execution of the trig:BaseSched schedule. It keeps track of the last time the schedule was triggered and every job triggered by the schedule.
 
 ├
trig:Triggered This object is used to track the execution of an individual job triggered by a schedule.
 
 
 ├
trig:ClientToken
 ├
version:Ep container for Version information
 
 ├
version:Application Application version Mo specifies the application version.


Inheritance
naming:NamedObject
 ├
top:System

Events
                



Faults
                



Fsms
                



Properties Summary
Defined in: top:System
address:IPv4 address  (top:System:address)
           The IP address of this system
scalar:Date currentTime  (top:System:currentTime)
           The current time on this system
naming:Descr
          string:Basic
descr  (top:System:descr)
           NO COMMENTS
os:IPv6
          address:IPv6
ipv6Addr  (top:System:ipv6Addr)
           IPv6 address of this system
top:Mode
          scalar:Enum8
mode  (top:System:mode)
           Specifies if this system is configured in standalone mode or HA pair
naming:Name
          string:Basic
name  (top:System:name)
           Overrides:naming:NamedObject:name
           The system name
naming:UserLabel
          string:Basic
owner  (top:System:owner)
           The owner of the UCS System
naming:UserLabel
          string:Basic
site  (top:System:site)
           The information about the site of this UCS system
scalar:Seconds systemUpTime  (top:System:systemUpTime)
           The number of seconds since this system was booted
Defined in: mo:TopProps
mo:ModificationChildAction
          scalar:Bitmask32
childAction  (mo:TopProps:childAction)
          
reference:Object dn  (mo:TopProps:dn)
           The Distinguished Name (dn) unambiguously identifies an object in the system.
The dn provides a fully qualified path from the top of the object tree, all the way to the object. It is built as a sequence of relative names separated by the "/" character.
For example:
< ... dn = "sys/chassis-5/blade-2/adaptor-1" />
reference:RN rn  (mo:TopProps:rn)
           The Relative Name (rn) uniquely identifies an object within a given context.
Note that a dn is comprised of a sequence of relative names. For example, the context "sys/chassis-1/blade-1/adaptor-1/host-eth-2" can be thought of as the following expression:
dn = <root object>/{rn}/{rn}/{rn}/{rn}/{rn}.
The rn can then be used to identify the object (for instance, "adaptor-1") within the context:
<... rn ="../" />
mo:InstSaclType
          scalar:Bitmask8
sacl  (mo:TopProps:sacl)
           The system acl property for each Managed Object. br/> This property is a 8 bit mask and supports the following values :-
a: del
b: mod
c: addchild
d: cascade

By default all Managed Objects have the following permissions
a: del
b: mod
c: addchild
This property is persisted in the db. If this property has a value none
it means, the user has read only permissions on this object.
mo:ModificationStatus
          scalar:Bitmask32
status  (mo:TopProps:status)
           This property controls the life cycle of a managed object

Properties Detail

address

Type: address:IPv4
Units: null
Encrypted: false
Access: admin
Category: TopLevelRegular
Property Validators:
Comments:
The IP address of this system

childAction

Type: mo:ModificationChildAction
Primitive Type: scalar:Bitmask32
Units: null
Encrypted: false
Access: implicit
Category: TopLevelChildAction
Property Validators:
Comments:
Constants
deleteAll 16384u NO COMMENTS
ignore 4096u NO COMMENTS
deleteNonPresent 8192u NO COMMENTS
DEFAULT 0 This type is used to

currentTime

Type: scalar:Date
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
The current time on this system

descr

Type: naming:Descr
Primitive Type: string:Basic
Like: naming:Described:descr
Units: null
Encrypted: false
Access: admin
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "256"
        Allowed Chars:
            Regex: [a-zA-Z0-9\[\]!#$%()*+,-./:;@ _{|}˜?&]+
Comments:
NO COMMENTS

dn

Type: reference:Object
Units: null
Encrypted: false
Access: implicit
Category: TopLevelDn
Property Validators:
Comments:
The Distinguished Name (dn) unambiguously identifies an object in the system.
The dn provides a fully qualified path from the top of the object tree, all the way to the object. It is built as a sequence of relative names separated by the "/" character.
For example:
< ... dn = "sys/chassis-5/blade-2/adaptor-1" />

ipv6Addr

Type: os:IPv6
Primitive Type: address:IPv6
Units: null
Encrypted: false
Access: admin
Category: TopLevelRegular
Property Validators:
    Regex: ˆ([0-9a-fA-F]{1,4}:){7,7}[0-9a-fA-F]{1,4}$|ˆ([0-9a-fA-F]{1,4}:){1,7}:$|ˆ([0-9a-fA-F]{1,4}:){1,6}:[0-9a-fA-F]{1,4}$|ˆ([0-9a-fA-F]{1,4}:){1,5}(:[0-9a-fA-F]{1,4}){1,2}$|ˆ([0-9a-fA-F]{1,4}:){1,4}(:[0-9a-fA-F]{1,4}){1,3}$|ˆ([0-9a-fA-F]{1,4}:){1,3}(:[0-9a-fA-F]{1,4}){1,4}$|ˆ([0-9a-fA-F]{1,4}:){1,2}(:[0-9a-fA-F]{1,4}){1,5}$|ˆ[0-9a-fA-F]{1,4}:((:[0-9a-fA-F]{1,4}){1,6})$|ˆ:((:[0-9a-fA-F]{1,4}){1,7}|:)$
Comments:
IPv6 address of this system
Constants
defaultValue "::" NO COMMENTS

mode

Type: top:Mode
Primitive Type: scalar:Enum8
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
Specifies if this system is configured in standalone mode or HA pair
Constants
unspecified 0 NO COMMENTS
stand-alone 1 Specifies this system is configured in standalone, non HA mode
cluster 2 Specifies this system is configured as an HA pair
DEFAULT unspecified(0) NO COMMENTS

name

Type: naming:Name
Primitive Type: string:Basic
Overrides:naming:NamedObject:name
Units: null
Encrypted: false
Access: admin
Category: TopLevelRegular
Property Validators:
    Regex: [a-zA-Z][a-zA-Z0-9-]{0,29}
Comments:
The system name

owner

Type: naming:UserLabel
Primitive Type: string:Basic
Units: null
Encrypted: false
Access: admin
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "32"
        Allowed Chars:
            Regex: [a-zA-Z0-9\[\]!#$%()*+,-./:;@ _{|}˜?&]+
Comments:
The owner of the UCS System

rn

Type: reference:RN
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRn
Property Validators:
Comments:
The Relative Name (rn) uniquely identifies an object within a given context.
Note that a dn is comprised of a sequence of relative names. For example, the context "sys/chassis-1/blade-1/adaptor-1/host-eth-2" can be thought of as the following expression:
dn = <root object>/{rn}/{rn}/{rn}/{rn}/{rn}.
The rn can then be used to identify the object (for instance, "adaptor-1") within the context:
<... rn ="../" />

sacl

Type: mo:InstSaclType
Primitive Type: scalar:Bitmask8
Units: null
Encrypted: false
Access: implicit
Category: TopLevelSacl
Property Validators:
Comments:
The system acl property for each Managed Object. br/> This property is a 8 bit mask and supports the following values :-
a: del
b: mod
c: addchild
d: cascade

By default all Managed Objects have the following permissions
a: del
b: mod
c: addchild
This property is persisted in the db. If this property has a value none
it means, the user has read only permissions on this object.
Constants
none 0 NO COMMENTS
del 1 NO COMMENTS
mod 2 NO COMMENTS
addchild 4 NO COMMENTS
cascade 8 NO COMMENTS
DEFAULT 0 NO COMMENTS

site

Type: naming:UserLabel
Primitive Type: string:Basic
Units: null
Encrypted: false
Access: admin
Category: TopLevelRegular
Property Validators:
    Range:  min: "0"  max: "32"
        Allowed Chars:
            Regex: [a-zA-Z0-9\[\]!#$%()*+,-./:;@ _{|}˜?&]+
Comments:
The information about the site of this UCS system

status

Type: mo:ModificationStatus
Primitive Type: scalar:Bitmask32
Units: null
Encrypted: false
Access: implicit
Category: TopLevelStatus
Property Validators:
Comments:
This property controls the life cycle of a managed object
Constants
removed 16u In a setter method: specifies that an object should be removed.
In the return value of a setter method: indicates that an object has been removed.
created 2u In a setter method: specifies that an object should be created. An error is returned if the object already exists.
In the return value of a setter method: indicates that an object has been created.
modified 4u In a setter method: specifies that an object should be modified
In the return value of a setter method: indicates that an object has been modified.
deleted 8u In a setter method: specifies that an object should be deleted.
In the return value of a setter method: indicates that an object has been deleted.
DEFAULT 0 This type controls the life cycle of objects passed in the XML API.

When used in a setter method (such as configConfMo), the ModificationStatus specifies whether an object should be created, modified, deleted or removed.
In the return value of a setter method, the ModificationStatus indicates the actual operation that was performed. For example, the ModificationStatus is set to "created" if the object was created. The ModificationStatus is not set if the object was neither created, modified, deleted or removed.

When invoking a setter method, the ModificationStatus is optional:
If a setter method such as configConfMo is invoked and the ModificationStatus is not set, the system automatically determines if the object should be created or modified.


systemUpTime

Type: scalar:Seconds
Units: null
Encrypted: false
Access: implicit
Category: TopLevelRegular
Property Validators:
Comments:
The number of seconds since this system was booted